Figure 23. The Converter Server Configuration Example
6.1.2.2 Client Configuration
In the client configuration, the user should set
Device IP Address
,
Device Port
,
Device Subnet
Mask
and
Device Default Gateway
to the appropriate values received from the network
administrator the same way as with the server configuration. After that, the user should set the
Device Port Type, Remote IP Address
and
Remote Port
to match the settings of the converter
in the server mode and activate the client mode by setting the
Auto Connect to Remote
to
Yes
.
The CAN network setup is done similarly to the server mode; the
Baud Rate
is set to the
desired baud rate (not necessarily the same as on the server) and the
Loopback Messages
is
set to
No
.
An example of the converter configuration in a client mode is presented in Figure 24.