UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
111 - 141
the control will convert the measured/received feedback into a percentage value using the scaling limits of
the control source/number as defined in Table 17.
Object Description
Index
2456h
Name
PID Feedback Number
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
PID
x
Feedback Number
Access
RW
PDO Mapping
No
Value Range
Default Value
x
2.4.40. Object 2457h: PID Control Response
This object defines the output profile for the PID control function block in a push-pull dual output system.
The options for this object are listed in Table 24.
Object Description
Index
2457h
Name
PID Control Response
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
PIDx Control Response
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (single output)