background image

Refer  elsewhere  for  corners,  slopes  and  other 
situations not illustrated here.

BRSCS SCREWS. install 4 screws into the top of each
post to secure the DRH under cap in position

AFGHR handrail to be snap fitted over Innerrail

AFGIR Innerrail

RETAINED  GASKET  to  the  outer  face  of  glass,
either SRB for 6mm and 8mm glass, or SRE for 
10mm  and  12mm  glass.  Must  be  slid  into  post 
prior to assembly.

TOUGHENED  GLASS,  of  appropriate  thickness, 
depending on the post spacing. Refer to engineering 
documents for all sizing and applications. Exposed
horizontal edges to be flat polished 

WEDGE GASKET to the inner face of glass, either 
SWE70  for  6mm  glass,  SWE50  for  8mm  glass, 
SWE55  for  10mm  glass,  or  SWE35  for  12mm 

glass.

AFG  RECESSED  POST. 
On  90°  corners  use  AFGEC & AFGIC

ABBAFG SETTING  BLOCKS  to  back  of  glazing  cavity.   

 

AKS  GLASS SEAT,  to  support  glass.  Attach  to  AIA
insert (press fit) 

AIA  INSERT  for  supporting  glass  by  transferring 
weight down to base plate or substrate.

CHEMSET Fixing - refer to engineering documents for
all sizing and applications

BPFGCF Baseplate (12mm Thick)

AFGI   I N F I L L .
To snap into rear of post

Luna Installation Manual

Summary of Contents for Luna SD9 Series

Page 1: ......

Page 2: ...Luna Installation Manual ...

Page 3: ...on to and without in any way limiting paragraphs a and b above and notwithstanding that Axiom may provide engineering drawings which if it does must be read in conjunction with Axiom s installation instructions i it is the Customer s responsibility to comply with all Australian laws all Standards including but not limited to AS1288 and AS1170 1 the Building Code and the requirements of all relevan...

Page 4: ...neering documents for all sizing and applications Exposed horizontal edges to be flat polished WEDGE GASKET to the inner face of glass either SWE70 for 6mm glass SWE50 for 8mm glass SWE55 for 10mm glass or SWE35 for 12mm glass AFG POST On 90 corners use AFGEC AFGIC ABBAFG SETTING BLOCKS to back of glazing cavity AKS GLASS SEAT to support glass Attach to AIA insert press fit AIA INSERT into screw f...

Page 5: ...ents and Warranty Insert screws until they are fully inserted All screws must be fully inserted tightened FV10 19 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty Insert screws until they are fully inserted All screws must be fully inserted tightened Luna Installation...

Page 6: ...te thickness depending on the post spacing Refer to engineering documents for all sizing and applications Exposed horizontal edges to be flat polished WEDGE GASKET to the inner face of glass either SWE70 for 6mm glass SWE50 for 8mm glass SWE55 for 10mm glass or SWE35 for 12mm glass AFG POSTwith notch out the bottom On 90 corners use AFGEC AFGIC CHEMSET Fixings refer to engineering documents for al...

Page 7: ...r screws is strictly not permitted and invalidates all Producer Statements and Warranty Insert screws until they are fully inserted All screws must be fully inserted tightened BRSCS Screws supplied by AXIOM GROUP Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty Insert screws until they are fully inserted All screws must be fully inserted tightened ...

Page 8: ...Refer to engineering documents for all sizing and applications Exposed horizontal edges to be flat polished WEDGE GASKET to the inner face of glass either SWE70 for 6mm glass SWE50 for 8mm glass SWE55 for 10mm glass or SWE35 for 12mm glass AFG RECESSED POST On 90 corners use AFGEC AFGIC ABBAFG SETTING BLOCKS to back of glazing cavity AKS GLASS SEAT to support glass Attach to AIA insert press fit A...

Page 9: ... Statements and Warranty Insert screws until they are fully inserted All screws must be fully inserted tightened FV10 19 FASTENERS Self tapping stainless steel countersunk screws supplied by AXIOM GROUP Use of other screws is strictly not permitted and invalidates all Producer Statements and Warranty Insert screws until they are fully inserted All screws must be fully inserted tightened Luna Insta...

Page 10: ...on the Inner Rail centreline Fig 2 shows a typical arrangement FIG 3 CONNECTION OF SLOPING RAILS TO POST BRSCS screws required 4 per posts on the outer groove lines of the Inner Rail Drill 5 5mm Ø fixing holes at the correct angle to the rail Fig 3 shows a typical arrangement Insert screws until they are fully inserted All screws must be fully inserted tightened Luna Installation Manual FIG 3 FIG ...

Page 11: ...anual GLAZING This section covers the measuring and Installation of the glass panes Ensure the correct thickness of toughened glass is used INSTALL GLASS Glass is to be installed by shuffle glazing Fit Setting block within the post to ensure glass is blocked in accordance with AS1288 and can not dislodge Baseplate Setting Blocks Refer below to select correct block for the post Lower Edge of Glass ...