Use a screwdriver to unscrew the three screws secured on
the back cover and the battery cover , then unscrew the
two screws under the battery cover.
¥
Separate the back cover from the top case.
¥
Replace the fuse only with specified ratings:
F 500mA/250V
∅
5
×
20.
¥
Replace the back cover and secure by the screws.
5.3 Battery replacement
Before replacing the battery, disconnect test
leads from any circuit under test, turn the meter
off and remove test leads from the input
terminals.
Use the following procedure:
¥
When the battery voltage drop below proper operation
range the
symbol will appear on the LCD display and
the battery need to be replaced.
¥
Set the meter to OFF state.
¥
Disconnect test leads from any inputs terminals.
¥
Use a screwdriver to unscrew the two screws secured on
the battery cover.
¥
Replace the battery with three new 1.5V batteries(AAA).
¥
Replace the battery cover by the two screws.