axing SKT 20-20M Quick Start Manual Download Page 4

Product description:

SKT 20-20M = Multituner - QAM twin module
SKT 40-20M = Multituner - QAM quattro module (SKT 40-24M with CI)
SKT 80-20M = Multituner - QAM octo module (SKT 80-22M with CI)
The modules transmodulates DVB-S/S2/T/T2/C/Cx  into DVB-T2.

Mounting and Installation:

Before inserting or changing a module, pull the mains plug of the 
headend base unit from the socket! 

The headend modules can be operated either in a headend base units 
(1) or stand-alone with the external power supply unit (2). 
The module is supplied with power by DC patch cable (3). While looping 
the modules through, a maximum of 3 x SKT 80-2x or 4 x SKT 20/40-2x 
can be connected together. 

It is imperative to use a power supply unit with sufficient output 
power for your application! 

At the input the modules have a remote supply voltage for the LNB. 

For 

receiving DVB-T/T2 or DVB-C the LNB power has to be switched 
off before connecting a antenna cabel to one of the HF inputs!

 

You will find this setting in the configuration in phase 1.

Display elements and connectors

1  2/4/8 × LED indicators  MPEG data stream modulator 

Error (red) = Fill level >95%
OK (green) = Fill level OK

2  4/8 × HF input 
3  1/2 × RJ-45 Ethernet port 
4  4/8 × HF input LED indicator:  
 

Orange = MPEG data stream present,  

 

Off = no MPEG data stream

5  Equipotential bonding connection
6  1/2 × HF output  
7  Fan
8  2 × DC input/output 

Notes

4

 Detailed operation instructions of the modules 
are available at www.axing.com

4

Observe the operation instructions of the used 
headend base unit!

4

Observe the operation instructions of the used 
power supply unit!

4

If the device is mounted in the headend base 
unit, the connection to the equipotential 
bonding has to be done via the headend base 
unit. 

4

If the module is mounted external a headend 
base unit the module and the power supply 
unit must be connected to the equipotential 
bonding according to EN 60728-11. Use the 
equipotential bonding connection at the 
device.

Common Interfaces

Note: 

Each CAM corresponds and 

gets access only to according tuner.
CAM 1 - tuner 1
CAM 2 - tuner 2 
CAM 3 - tuner 3
CAM 4 - tuner 4

CAM1

CAM2

CAM3

CAM4

CAM1

left

CAM1
right

Configuration:

The device is configured via the graphical user interface of the 
integrated web interface. To access the user interface, you need a 
standard PC/laptop with a network interface and the actual 
version of the installed web browser. To connect the network 
interface of the module to the computer, you need a commercially 
available network cable.
The SKT 80-2x contains two separate units. Each unit has its own 
web interface and its own static IP address. 

Accessing the configuration interface:

Default IP address of the SKT 20-2x: 

192.168.0.145

Default IP address of the SKT 40-2x: 

192.168.0.145

Default IP address of the SKT 80-2x, left side:  

192.168.0.145 

Default IP address of the SKT 80-2x, right side:  

 192.168.0.146

Subnet mask: 

255.255.255.0

4

Change the IP address of your PC/laptop, e.g. to 192.168.0.11.

4

 Now enter the IP address 192.168.0.145 in the web browser.

The configuration screen is password-protected:

4

 Enter the default password Ramsen8262. 

4

 Click the "Enter password" button and then the "Open page" 
button. 

4

 This will open the start page. 

4

After the first log-in, the password should be changed.

Scope of delivery:

1 × Headend module
1 × DC connection cable 
1 × Quick start guide

1

3

2

3