axing SES 984-06 Operation Instructions Download Page 3

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2021-01-07

Technical improvements, changes in design, printing- and other errors expected.

Safety advices:

 

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines. No liability will be 
assumed in the case of faulty installation and commissioning.

 

Before opening the equipment pull out the power plug or remove the 
power supply, otherwise there is danger of electrocution. This is also 
valid for cleaning the equipment or working on the connections. 

 

Only use the mains cable connected to the device. Never replace any 
parts or make any modifications on the mains cable. Otherwise there is a 
risk of mortal injury for which we cannot be held liable.

 

Providing that a serviceable fuse exists, the power plug must be pulled 
out before changing the fuse. Defective fuses may only be replaced with 
standard compliant fuses that have the same nominal value.

 

The equipment may only be operated in dry rooms. In humid rooms or 
outdoors there is danger of short-circuit (caution: risk of fire) or  
electrocution.

 

To prevent damage to your equipment and to avoid possible peripheral 
damages, the devices foreseen for wall mounting may only be installed 
on a flat surface.

 

Choose the location of installation or mounting so that the power plug 
can be reached and pulled out of the socket easily in case of danger. 
Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. The mains cable as well as feeder lines may not be 
damaged or clamped by objects of any kind. 

 

Choose the location of installation or mounting so that under no  
circumstances liquids or objects can get into the equipment (e.g.  
condensation, water coming from leaking roofs or flowing water, etc.).

 

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices 
that are equipped with heat sinks or ventilation slots must under no 
circum-stances be covered or blocked. Also ensure for a generous air 
circulation around the equipment. In this way you avoid possible damage 
to the equipment as well as a risk of fire caused by overheating.  
Absolutely avoid that cables come near any source of heat (e.g.  
radioators, other electrical devices, chimney, etc.).

Technical data:

Frequency range TERR

5…862 MHz 

Frequency range SAT (quattro LNB | wideband LNB)

950…2150 MHz | 250…2350 MHz

Input level (AGC)

60… 90 dBµV

Inputs

9

Subscriber ports

8

User bands

8 × 4

1

User band frequencies

1331/1382/1433/1484 MHz

Standards

EN 50494, EN 50607

Tap loss TERR

22 dB

Output level SAT @ 60…90 dBµV input level

83/82 dBµV

Through loss TERR

2 dB ±1,5 dB

Through loss SAT

5 dB ±1,5 dB

Isolation H/V

30 dB

Return loss (inputs/outputs)

≥ 10 dB

Ambient temperature range (acc. to EN 60065)

-20…70°C

Connectors

F

LNB supply voltage

12 V

Max. LNB supply current (total | per LNB)

2000 mA | 500 mA

Current consumption from STB (SCR/CSS)

180 mA 

Equipotential bonding connection

4 mm

2

Dimensions (W × H × D) appr.

205 x 310 x 63 mm

1

 there are 4 user bands at each output

SES 984-06

premium

-line

Single cable multiswitch II (SCR)
Operation instructions

WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of 
as residual waste, it must be disposed of separately.

CE Confirmation Declaration

Hereby, AXING AG declares that the device is in compliance with Directive 2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet 
address: 

https://axing.com/en/downloads/ce/