Field of application:

The devices are only suitable for distributing radio and television signals inside 
the house! If a device is used for other purposes, no warranty is given!

Connectors, switches, mounting brackets:

4 Inputs for Universal Quattro LNB

Rotary switch

Quattro / Wideband

2 Inputs for Wideband LNB 1

2 Inputs for Wideband LNB 2

DC connector

Terrestrial input

Subscriber output 1

equipotential bonding 

connector

Subscriber outputs 2

Trunk outputs for cascading

Mounting bracket

Mounting bracket

Mounting bracket

Mounting bracket

Equipotential bonding and mounting:

To avoid dangerous power surges (e.g. risk of fire and danger of life) the device 
must be connected to the equipotential bonding according to EN 60728-11.

 

Use the equipotential bonding connection at the device.

 

To connect the outer conductors of the coaxial cables to the equipotential 
bonding, use, for example, a QEW earthing angle with SAK patch cables at 
the inputs and CFA 7-01 earth connection blocks at the subscriber outputs 
of the device. 

 

Mount the device on a flat surface. Use appropriate mounting screws and 
the mounting brackets of the device.

RF installation:

 

Use highly shielded coaxial cables with F connectors. Suitable cables and 
connectors can be found in the current AXING at www.axing.com.

Quattro LNB: 

 

Set the rotary switch to Quattro.

 

Connect the SAT inputs (LV, LH, HV and HH) of the multiswitch to the LNB of 
your SAT reception antenna.

Wideband LNB:

The single-cable multiswitches can be used with wideband LNB with an 
oscillator frequency of 10.4 GHz. 

 

Set the rotary switch to WB.

 

Connect the first wideband LNB to the left connectors V and H and connect 
the second wideband LNB to the right connectors V and H.

Terrestrial:

 

Feed the output signals of a terrestrial amplifier or a CATV amplifier into the 
terrestrial input.

Subscriber outputs

 

Connect the subscriber outputs of the multiswitch to the antenna wall 
outlets.

Outputs and user bands:

The SES 5216 has two subscriber outputs.  At each of these, 16 user bands are 
available. 

For receivers according to EN 50607, all 16 user bands can be used.

UB 1

975 MHz

UB 9

1375 MHz

UB 2

1025 MHz

UB 10 1425 MHz

UB 3

1075 MHz

UB 11 1475 MHz

UB 4

1125 MHz

UB 12 1525 MHz

UB 5

1175 MHz

UB 13 1575 MHz

UB 6

1225 MHz

UB 14 1625 MHz

UB 7

1275 MHz

UB 15 1675 MHz

UB 8

1325 MHz

UB 16 1725 MHz

Eight user bands can be used for 
EN 50494 receivers.

 

Assign each user band only once. 

 

Use programmable single-cable antenna wall outlets SSD 6-xx for 
interference-free operation.

 

For multi-tuner devices (Twin or Quatto), assign the appropriate number of 
user bands to the antenna wall outlet. 

 

Connect the user band with the highest frequency (UB 16) using the 
shortest cable.

2 x SCO 2-10

Wideband-LNB

DVB-C

CFA 7-01

UB7/8

SAT TV

TWIN TUNER

EN 50607

UB5/6

SAT TV

TWIN TUNER

EN 50607

UB3/4

SAT TV

TWIN TUNER

EN 50607

UB1/2

SAT TV

TWIN TUNER

EN 50607

UB7/8

SAT TV

TWIN TUNER

EN 50494

UB5/6

SAT TV

TWIN TUNER

EN 50494

UB3/4

SAT TV

TWIN TUNER

EN 50494

UB1/2

SAT TV

TWIN TUNER

EN 50494

UB11/12

SAT TV

TWIN TUNER

EN 50607

UB9/10

SAT TV

TWIN TUNER

EN 50607

UB15/16

SAT TV

TWIN TUNER

EN 50607

UB13/14

SAT TV

TWIN TUNER

EN 50607

SES 5216-06

CFA 11-00

QEW 5-06

SZU 99-06

5 × SAK 21-02

Coax

Equipotential bonding

Cascading:

 

If you do not connect any further single cable multiswitches, then 
terminate the cascade outputs at the bottom of the device with 
DC-decoupled 75 Ohm terminating resistors.

 (e. g. CFA 11-00 not 

included in delivery).

Up to three single cable multiswitches can be connected to one cascade. 

 

Connect the outputs of the single cable multiswitch with the inputs of 
the next single cable multiswitch units. 

 

Use F/F Quickfix adapters CFA 4-01 or highly shielded coaxial cables with 
F-connectors (not included).

 

Terminate the outputs of the last device with DC-isolated 75 Ohm 
terminating resistors 

(e. g. CFA 11-00 not included in delivery)

.

Power supply:

The single-cable multiswitch is supplied via an external power supply 
unit SZU 99-06 (not included in the delivery). This power supply unit 
also supplies the connected LNBs and any cascade modules that may be 
connected.

The total supply current via the DC connection must not exceed 1 A.

 

Check that the current consumption of all connected components does 
not exceed 1 A. If necessary, connect another external power supply unit 
SZU 99-06 to a cascade unit.

Application example: 

Eight TV devices with twin tuners which support 

EN 50607

 are connected 

to subscriber output 1. Four TV devices with twin tuners which only support 

EN 50464

 are connected to subscriber output 2 (for further application 

examples, please refer to www.axing.com). If different receivers (EN 50607/
EN 50464) are connected to one subscriber output, ensure that the user 
bands are assigned correctly.

Single cable or legacy mode:

The single-cable multi-switch automatically detects which mode the 
connected receiver requires and provides the appropriate signal (in single-
cable mode the user bands, in legacy mode the polarisation level). The 
detection is performed separately for each subscriber output. 

The legacy mode cannot be used with programmable antenna wall 
outlets SSD 6-xx! 
The legacy mode cannot be used with wideband LNBs!

To prevent a receiver which is not suitable for single-cable operation 
switching the subscriber output to legacy mode, we recommend 
programmable SSD 6-xx antenna wall outlets.

Reviews: