background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2020-10-07

Technical improvements, changes in design, printing- and other errors expected.

 

Observe the safety instructions supplied with the device! 
They are also available at the following Internet address: 

https://download.axing.com/BAs/Sicherheitshinweise_9sprachig.pdf

 

Use the device only as described in these operating instructions and in 
particular in accordance with the state of the art.  
If the device is used for other purposes, no warranty will be assumed!

Technical data:

SES 5216-06

premium

-line

Single cable multiswitch II (SCR)
Operation instructions

CE Confirmation Declaration

Hereby, AXING AG declares that the device is in compliance with Directive 2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet 
address: 

https://axing.com/en/downloads/ce/

WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of 
as residual waste, it must be disposed of separately.

Type

SES 5216-06

Inputs

Number

5

Frequency range

5…862 MHz @ TERR

250…2350 MHz @ SAT

LNB voltage

18 V

Level (AGC)

60… 90 dBµV

Isolation V | H.

25 dB

Subscriber ports

Number

2

Supported standards

EN 50494, EN 50607

Tap loss TERR

17 dB ±2,0 dB

Frequency range (SAT)

950…2150 MHz

User bands

2 × 16

User band frequencies

975/1025/1075/1125/1175/1225/1275/1325 MHz 

@ EN 50494/50607

1375/1425/1475/1525/1575/1625/1675/1725 MHz 

@ EN 50607

Output level SAT (SCR/CSS)

98 dBµV ±2,0 dB

Output level SAT (Legacy)

85 dBµV ±2,0 dB

Current consumption from STB (SCR/
CSS)

180 mA 

Current consumption from STB 
(Legacy)

60 mA

Trunk outputs

Number

5

Through loss TERR

2 dB ±1,0 dB

Through loss SAT

2 dB ±2,0 dB

Connectors

Connector type
Return loss

≥ 10 dB

General

Operating voltage

18 VDC

Current consumption

max. 250 mA 

Connector DC

F-female

Maximum supply current 

1 A*

Equipotential bonding connection

4 mm²

Operating temperature range 
(acc. to EN 60065)

-20…50°C

Dimensions (W × H × D) appr.

140 x 100 x 63 mm

Comments

* The LNBs, the SES 5216-06 and any connected 

cascade units are supplied via the DC input.

Reviews: