background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2020-08-25

Technical improvements, changes in design, printing- and other errors expected.

Safety advices:

 

Installation and repairs to the equipment may only be carried out by 

technicians observing the current VDE guidelines. No liability will be 

assumed in the case of faulty installation and commissioning.

 

Before handling the device, pull out the mains plug, otherwise there is 

danger to life. This also applies if you clean the device or work on the 

connections.

 

Only use the mains cable connected to the device. Never replace any 

parts or make any modifications on the mains cable. Otherwise there is a 

risk of mortal injury for which we cannot be held liable.

 

If a replaceable fuse is available, pull the mains plug before changing 

the fuse. Replace damaged fuses only with standard fuses of the same 

nominal value.

 

The equipment may only be operated in dry rooms. In humid rooms or 

outdoors there is danger of short-circuit (caution: risk of fire) or electro-

cution.

 

The mains plug is used as a disconnecting device from the mains voltage 

both during service and in case of danger and must therefore be reacha-

ble and usable at all times. After connection to the mains, the device is in 

operation. 

 

To prevent damage to your equipment and to avoid possible peripheral 

damages, the devices foreseen for wall mounting may only be installed 

on a flat surface.

 

Choose the location of installation or mounting such that children may 

not play unsupervised near the equipment and its connections. 

 

The location of installation or mounting must allow a safe installation of 

all cables connected. The mains cable as well as feeder lines may not be 

damaged or clamped by objects of any kind. 

 

Absolutely avoid that cables come near any source of heat (e.g.  

radioators, other electrical devices, chimney, etc.).

 

Choose the location of installation or mounting so that under no  

circumstances liquids or objects can get into the equipment (e.g.  

condensation, water coming from leaking roofs or flowing water, etc.).

 

Avoid exposure of the equipment to direct sunlight and to other heat 

sources (e. g. radiators. other electrical devices, chimney, etc.). 

 

Devices that are equipped with heat sinks or ventilation slots must under 

no circum-stances be covered or blocked. Also ensure for a generous air 

circulation around the equipment. In this way you avoid possible damage 

to the equipment as well as a risk of fire caused by overheating. 

 

In case of damage, interrupt the power supply immediately.

 

Do not try to repair the device. This device should only be serviced or 

repaired by qualified service personnel. Contact your distributor for more 

information.

 

Do not open the device.

 

For disassembly always pull the mains plug first and disconnect the 

power supply cable from the connected device.

SPU 94-09 | SPU 96-09
SPU 910-09 | SPU 916-09

premium

-line

Multiswitches

Operation instructions

Technical data:

CE Confirmation Declaration

Hereby, AXING AG declares that the device is in compliance with Directive 2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet 
address: 

https://axing.com/en/downloads/ce/

WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of 
as residual waste, it must be disposed of separately.

Type

SPU 94-09

SPU 96-09

SPU 910-09

SPU 916-09

Inputs

Number

9

Frequency range

5…65 MHz | 85…862 MHz | 950…2200 MHz

Attenuator adjustment range 

TERR,

 switchable to 

passive

-

20 dB

20 dB

20 dB

Subscriber ports

Number

4

6

10

16

Switch commands

13/18 

V,

 0/22 kHz,

 DiSEqC 2.0

Max.

 output level  SA

T (3rd or

-

der SA

T EN 50083

-3 35dB KMA,

 2 sender test method)

94 dBµV

Current consumption per port (without LNB supply)

25 mA

Trunk outputs

Number

-

9

9

9

Max.

 output level 

TERR (3rd or

-

der EN 50083

-3,

 60 dB KMA)

-

103 dBµV

103 dBµV

103 dBµV

Max.

 output level trunk SA

T (3rd or

-

der EN 50083

-3,

 35 dB KMA,

 2 sender test method)

-

113 dBµV

112 dBµV

111 dBµV

Gener

al

Switching power supply

90…250 

V~ | 47-63 Hz | 18 

V=/1,2 

A

Operating temperature range (acc.

 to EN 60065)

-20…+50°C

Dimensions (W × H × D) appr

.

255 × 145 × 85 mm

255 × 145 × 85 mm

255 × 180 × 85 mm

255 × 255 × 85 mm

Protection class

IP 20

You find the detailed technical data by entering the article in the search field at www.axing.com.