![AXEM Technology M-2900 User Manual Download Page 19](http://html1.mh-extra.com/html/axem-technology/m-2900/m-2900_user-manual_3036092019.webp)
AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE – [email protected] – +33 (0)1 41 94 11 85 – www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File : 20190517_S-8800_&M-2900_User_guide.docx S-
8800 M 2900
Version : V1.0
19/27
After choosing the tag, please click
Select
and the screen will display as follows:
We could see that the column on the left for
Selected Tag
has been selected. Next, all the operations
are based on the tag with this EPC NO.
If you want to cancel the match of EPC, just deselect the column for
Selected Tag
, as below:
3.4.6
Error Display Might Be Returned
Errors occur if wrong operations done:
◆
Inventory success, access failure:
There are two steps to get access to tags: firstly, tag inventory; secondly, access tags. Picture above
shows the inventory is successful, but we can’t access to tags.
Two reasons why:
1. Parameters incorrect: for example, zones(password/ EPC/ TID/ User) to be read do not exist.
2. Tags beyond the area that the RF could cover: distance when accessing to tags is about 60%-
70% of tag inventory; in this case, please proceed the tag closer to antenna.