AXEM Technology M-2900 User Manual Download Page 1

 

AXEM Technology

  

11 rue Auguste Perret, 94042 Créteil, FRANCE – [email protected] – +33 (0)1 41 94 11 85 – www.axemtec.com 

Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 € 

File :  20190517_S-8800_&M-2900_User_guide.docx  S-

8800  M 2900 

Version : V1.0 

 

1/27 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

S-8800, M-2900 

User guide

 

Summary of Contents for M-2900

Page 1: ...E info axemtec com 33 0 1 41 94 11 85 www axemtec com Siret 45071140300045 APE 4652Z RCS CRETEIL 450711403 N TVA intracom FR05450711403 Capital 500 000 00 File 20190517_S 8800_ M 2900_User_guide docx...

Page 2: ...3 Connecting Data Line to Reader 7 3 1 4 Step 4 Operating Reader via Demo 8 3 2 Setting RF Parameter 10 3 2 1 Setting RF Output Power 10 3 2 2 Setting RF Spectrum 11 3 2 3 Antenna Connection Detector...

Page 3: ...5071140300045 APE 4652Z RCS CRETEIL 450711403 N TVA intracom FR05450711403 Capital 500 000 00 File 20190517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Version V1 0 3 27 3 6 3 Set GPIO Level 23 3 6 4...

Page 4: ...85 www axemtec com Siret 45071140300045 APE 4652Z RCS CRETEIL 450711403 N TVA intracom FR05450711403 Capital 500 000 00 File 20190517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Version V1 0 4 27 1 B...

Page 5: ...om 33 0 1 41 94 11 85 www axemtec com Siret 45071140300045 APE 4652Z RCS CRETEIL 450711403 N TVA intracom FR05450711403 Capital 500 000 00 File 20190517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Ve...

Page 6: ...e 20190517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Version V1 0 6 27 3 Reader Configurations 3 1 Initial Use 3 1 1 Step 1 Powering the Reader Plug the power cable in with the indicator light on a...

Page 7: ...0517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Version V1 0 7 27 3 1 3 Step 3 Connecting Data Line to Reader Method NO 1 You can connect the reader to your PC via RS 232 serial port as illustrated...

Page 8: ...is low level GPIO1 ON Status GPIO1 is low level TCP IP ON Status is TCP IP communication Blank RS232 ON Status is RS232 communication 3 1 4 Step 4 Operating Reader via Demo Put the UHFDemo exe reader...

Page 9: ...ion History will display as below If the reader is connected via TCP IP please follow those steps Ensure that an Ethernet Card has been installed in the PC Ensure that PC and reader in the same networ...

Page 10: ...Reader Identifier the following screen displays Now the reader has been connected to PC successfully 3 2 Setting RF Parameter After connecting the reader with PC we need to set some basic RF parameter...

Page 11: ...t frequency and end frequency to the same carrier frequency the reader will work under fixed frequency When the parameter setting completes RF carrier frequency of reader will be randomly hopping in t...

Page 12: ...EPC number at the same time This is the core funtion of UHF RFID Reader and one of the standards to judge a reader s performance 3 3 1 Real Time Mode Buffer Mode The most commonly used mode for tag i...

Page 13: ...s when you set the value to 2 2 Click Inventory you will find that the EPC number is uploaded immediately and it is real time updating The reader will keep inventory unless you click stop as shown bel...

Page 14: ...03 N TVA intracom FR05450711403 Capital 500 000 00 File 20190517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Version V1 0 14 27 Method NO 2 Buffer Mode 1 Click Inventory the screen will display as be...

Page 15: ...respond to the other new command Sometimes when 500 800ms is not accepted we need to use Fast Switch Antenna function There are two methods to achieve fast switching antenna Method NO 1 Set the value...

Page 16: ...20190517_S 8800_ M 2900_User_guide docx S 8800 M 2900 Version V1 0 16 27 3 4 Accessing ISO 18000 6C Tag Click Access Tag and the screen will display as following 3 4 1 Read tags You can type the para...

Page 17: ...icture as below shows two tags have been identified successfully 3 4 2 Write Tags The area of Write Tag is the same as Read Tag but you need to provide access password and information of write data Wh...

Page 18: ...Kill Tags Password is necessary which can t be 00 00 00 00 before Kill Tags Therefore to kill a tag please change the content of password via Write Tag Operation first When tag is killed successfully...

Page 19: ...ns are based on the tag with this EPC NO If you want to cancel the match of EPC just deselect the column for Selected Tag as below 3 4 6 Error Display Might Be Returned Errors occur if wrong operation...

Page 20: ...password Reason why wrong password is set No tags to be operated Reason why Tags beyond the area that the RF could cover For more information about the operation history returned please defer to the...

Page 21: ...27 Each time when the reader identifies a tag s UID the buzzer will sound with a short beep If the buzzer sounds with a long beep it means the reader start the anti collision function and identifies m...

Page 22: ...ta is not limited Multi byte data could be written If error occurs the reader will stop writing but data which has been written will not change thus reader will return the number of bytes which have b...

Page 23: ...rdingly Please use this function based on practical application 3 6 2 Operating Temperature Monitoring Reader will generate heat under intensive work Users can monitor the internal temperature via bui...

Page 24: ...S 8800 M 2900 Version V1 0 24 27 The image of GPIO port as below PIN ID Function Equivalent Circuit Instructions PIN 1 GPIO 1 Input Voltage between PIN 1 2 PIN 3 4 12V Hetero polarity LED equivalent...

Page 25: ...s 3 6 4 Setting Buzzer Status Reader s working status is provided to users through the Buzzer Three ways to set the buzzer 1 Quite turn off the buzzer 2 Beep after an inventory round set it as beep ea...

Page 26: ...6 5 Charging The Serial Communication Baud Rate Reader supports two kinds of baud rate 38400 bps and 115200 bps You can set baud rate as below This setting will be stored even if the power is cut off...

Page 27: ...nterface Demo provides an important function of recording serial transmission so that users can quickly grasp the content of communication protocol in practice Please defer to the screenshot below and...

Reviews: