139
FIRST DEVICE START |MPX
TIGER E5 · User Manual · ENG
Pilot Min Level Control : if the Mpx pilot is under the threshold selected here the signal is not valid.
RDS Min Level Control : if the RDS level is under the threshold selected here the signal is not valid.
Peak Max Control : If the peak of the MPX level is higher then this value the signal is not valid.
Audio Level Control: If the Audio Level is under the threshold selected here the signal is not valid.
Out of Band Noise: If the Noise level is higher then this value the signal is not valid. (Out of Band Noise > 60 kHz)
Narrow Pilot Noise: If the Noise level is higher then this value the signal is not valid. (15 kHz< Narrow Pilot Noise < 23 kHz)
RDS PI Validation: If the PI is 0000 the RDS PI Validation is disable. In the other cases the signal is valid only if SourceA PI = RDS PI Validation.