FM VERSION DESCRIPTION
ENG
Page 23
EXAMPLE N° 1
–
controlling the SPLIT function from a TTL command
Apply an external TTL signal through a 470 Ohm carbon resistor to the photodiode 1 (pins 6 and 1). Max current
allowed: 10 mA. Nominal: 5 mA
EXAMPLE N° 2
–
controlling the SPLIT function from a clean contact
shortcut pin 9 and 1 and shortcut pin 15 and pin 6 via an external switch.