AXE MMR Series Manual Download Page 4

 

Rev  1.0 

 
 



 

9-1 

SCALE (Display Scale 
setting page) 
Value on EEPROM reset=1 



 

1.Decide scale with

or

or

key(0.0001~9.9999) 

2.Press

key enter data and return normal display 

RPM(scale = 0.0001~9.9999), LINE-SPEED(rotation diameter = 
0.0001~9.9999M) 

 Step 

Parameter mark description 

Parameter mark  Operation manual 

10 

Normal display 



 

Press

/A-ADJkey about 3 sec,into AZERO adjustment page 



 

10-1 

AZERO(Analog Output 
Zero Adjustment page) 
Value on EEPROM reset=0 



 

1.Adjustment analog output zero with

or

or

key(

±

9999) 

2.Press

key enter data and into ASPAN adjustment page 



 

10-2 

ASPAN(Analog Output   
Span Adjustment page) 
Value on EEPROM reset=0 



 

1.Adjustment analog output span with

or

or

key(

±

9999) 

2.Press

key enter data and return normal display 

Appendix  Error Mark description 

Error Mark 

Analyze & Description 

Input over range error 
detect 



 

Input signal over range(0~50KHz)  

Display over range error 
detect 



 

Input signal over display range(99999)  



 



 

EEPROM error detect   



 

1.External interference when EEPROM read/write 
2.EEPROM write over 100 million times(guarantee 10 years) 
Please power reset,if still display E-00,doing following 
step: 
1.

 

E-00 & No alternate display for inquire reset EEPROM 

2.

 

Decide Yes with  or  key,press  key return normal  

display 

3.

 

EEPROM was reset,Please follow step 1~10 set again 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 