AXE MMR Series Manual Download Page 2

 

Rev  1.0 

Key Introduce 

Operation Manual 

Key Function 

1.In normal display,The key function is call out setting group 
2.In parameter setting page,The key function is data Enter , and goto next page 

Key Function 

1.In normal display,The key function is call out alarm value setting page 
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can 
press shift key into setting procedure,The display is lock parameter data,this time must let off key 
about 0.2 sec,press again,the cursor(twinkle express)is cycle moving left. (Key Response about 0.2 
sec) 

Key Function 

1.In normal display,The key function is call out adjustment display scale page 
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can   
press up key into setting procedure,The display is lock parameter data,this time must let off key 
about 0.2 sec,press again,the parameter data will increment. (Key Response about 0.2 sec)   

Key Function 

1.In normal display,The key function is call out adjustment analog output ZERO&SPAN page 
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can 
press down key into setting procedure,The display is lock parameter data,this time must let off key 
about 0.2 sec,press again the parameter data will decrement. (Key Response about 0.2 sec)   

&

Key Function 

In setting group or setting page press 

&

  key return normal display,but if in setting page the 

modify data will be lost   

No Key in anything 

In setting group or setting page no key in anything about 2 minutes,return normal display,but if in   
Setting page the modify data will be lost 

Step 

Parameter Mark Description  Parameter Mark  Operation Manual 

Normal display 



 

Press 

/FUNC key into P.COD setting page 



 

P.COD(Pass code input page) 
 



 

1.Key in 5 digit pass code with 

or

or

key 

2.Press 

key,the pass code is right into setting group , otherwise   

  return normal display 

SYS(System setting group) 



 

 

ROP(Alarm setting group) 



 

 

AOP

(Analog output setting group)

 



 

 

DOP

(Communication setting group)

 



 

1.

 

Select setting group with 

  key 

2.

 

Press

key into setting page of selection setting group 

 

SYS(System setting group) 



 

Press

key decide SYS setting group , press

key into Dp setting page 



 

4-1 

DP(Decimal Point setting 
page)Default=0 

 

1.

 

Decide decimal point position with

or

  key (0 to 4) 

2.

 

Press

key enter data and into TYPE setting page 



 

4-2 

TYPE(Display Type) 
Default=RPM 



 

1.Decide display type with

or

key(RPM/LINE) 

2.Press

key enter data,If select LINE into UNIT setting page, 

otherwise into PPR setting page 



 

4-3 

UNIT(Line Speed Unit) 
Default=METER 



 

1.Decide line speed unit with 

or

key(METER/FOOT/YARD) 

2.Press

key enter data and into PPR setting page 



 

4-4 

PPR(Pulse Per Revolution) 
Default=1 



 

1.Decide pulse per revolution with

&

&

key(1~99999) 

2.Press

key enter data and into TBASE setting page 



 

4-5 

TBASE (Sampling Time 
Base) 
Default=0.1 



 

1.Decide sampling time base with

&

&

key(0.1~99.9

2.Press

key enter data and into AVG setting page 

 



 

4-6 

AVG (Display Average 
times) 
Default=1 



 

1.Decide display average times with

&

&

key(1~99) 

2.Press

key enter data and into CODE setting page 

 



 

4-7 

CODE(Pass Code) 
Default=0 



 

1.Decide pass code with

&

&

key(0~99999) 

2.Press

key enter data and into LOCK setting page 



 

4-8 

LOCK(Panel Lock) 
Default=NO 



 

1.Decide panel lock with

&

key(NO or YES) 

2.Press

key enter data and return SYS setting group 

Reviews: