Rev 1.0
Key Introduce
Operation Manual
Key Function
1.In normal display,The key function is call out setting group
2.In parameter setting page,The key function is data Enter , and goto next page
Key Function
1.In normal display,The key function is call out alarm value setting page
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can
press shift key into setting procedure,The display is lock parameter data,this time must let off key
about 0.2 sec,press again,the cursor(twinkle express)is cycle moving left. (Key Response about 0.2
sec)
Key Function
1.In normal display,The key function is call out adjustment display scale page
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can
press up key into setting procedure,The display is lock parameter data,this time must let off key
about 0.2 sec,press again,the parameter data will increment. (Key Response about 0.2 sec)
Key Function
1.In normal display,The key function is call out adjustment analog output ZERO&SPAN page
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can
press down key into setting procedure,The display is lock parameter data,this time must let off key
about 0.2 sec,press again the parameter data will decrement. (Key Response about 0.2 sec)
&
Key Function
In setting group or setting page press
&
key return normal display,but if in setting page the
modify data will be lost
No Key in anything
In setting group or setting page no key in anything about 2 minutes,return normal display,but if in
Setting page the modify data will be lost
Step
Parameter Mark Description Parameter Mark Operation Manual
1
Normal display
Press
/FUNC key into P.COD setting page
2
P.COD(Pass code input page)
1.Key in 5 digit pass code with
or
or
key
2.Press
key,the pass code is right into setting group , otherwise
return normal display
3
SYS(System setting group)
ROP(Alarm setting group)
AOP
(Analog output setting group)
DOP
(Communication setting group)
1.
Select setting group with
key
2.
Press
key into setting page of selection setting group
4
SYS(System setting group)
Press
key decide SYS setting group , press
key into Dp setting page
4-1
DP(Decimal Point setting
page)Default=0
1.
Decide decimal point position with
or
key (0 to 4)
2.
Press
key enter data and into TYPE setting page
4-2
TYPE(Display Type)
Default=RPM
1.Decide display type with
or
key(RPM/LINE)
2.Press
key enter data,If select LINE into UNIT setting page,
otherwise into PPR setting page
4-3
UNIT(Line Speed Unit)
Default=METER
1.Decide line speed unit with
or
key(METER/FOOT/YARD)
2.Press
key enter data and into PPR setting page
4-4
PPR(Pulse Per Revolution)
Default=1
1.Decide pulse per revolution with
&
&
key(1~99999)
2.Press
key enter data and into TBASE setting page
4-5
TBASE (Sampling Time
Base)
Default=0.1
1.Decide sampling time base with
&
&
key(0.1~99.9
秒
)
2.Press
key enter data and into AVG setting page
4-6
AVG (Display Average
times)
Default=1
1.Decide display average times with
&
&
key(1~99)
2.Press
key enter data and into CODE setting page
4-7
CODE(Pass Code)
Default=0
1.Decide pass code with
&
&
key(0~99999)
2.Press
key enter data and into LOCK setting page
4-8
LOCK(Panel Lock)
Default=NO
1.Decide panel lock with
&
key(NO or YES)
2.Press
key enter data and return SYS setting group