AOP(Analog output setting 
group) 



 

1.Press 

 key decide AOP setting group , press 

 key into ANLO 

setting page 



 

6-1 

ANLO(Analog Output Zero-     
According to Display)   
Default = 0 



 

1. Decide ANLO with 

 or 

 key (-19999~99999) 

2. Press 

 key enter data and into ANHI setting page 

 



 

6-2 

ANHI(Analog Output Span-   
According to Display ) 
Default = 99999 



 

1. Decide ANHI with 

 or 

 key (-19999~99999) 

2. Press 

 key enter data and into AZERO setting page 



 

6-3 

AZERO(Analog Output 
Zero Adjust)   
Default = 0 



 

1. Adjustment analog output zero with 

 or 

 key (

±

5999) 

2. Press 

 key enter data and into ASPAN adjustment page 

 



 

6-4 

ASPAN(Analog Output   
Span Adjust)   
Default = 0 



 

1. Adjustment analog output span with 

 or 

 key (

±

5999) 

2. Press 

 key enter data and return AOP setting group 

 

DOP(Communication setting 
group) 



 

1.Press 

 key decide DOP setting group, press 

 key into ADDR 

setting page 



 

7-1 

ADDR(Communication –Addr
ess )   
Default = 0 



 

1.Decide address with 

 or 

 key(0~255) 

2.Press

key enter data and into BAUD setting page

 

Note: When setting value is greater then 255,it will be return to zero. 



 

7-2 

BAUD(Communication Baud 
Rate) 
Default = 19200 



 

1. Decide baud rate with 

 key (38400,19200,9600,4800,2400) 

2. Press 

 key enter data and into PARI setting page 



 

7-3 

PARI(Communication Parity   
Check)   
Default = n.8.2. 



 

1.Decide Parity Check with 

 key(n.8.2.,n.8.1.,even,odd) 

2.Press

key enter data and 

return DOP setting group 

 

Step  Parameter mark description  Parameter mark 

Operation manual 

Normal display 



 

Press

/ALARM key about 3 sec, into AL1 setting page

 



 

8-1 

AL1 (Alarm 1) 
Default = 0 



 

1. Decide alarm value 1 with 

 or 

 key (0~99999) 

2. Press 

 key enter data and into AL2 setting page 

 



 

8-2 

AL2 (Alarm 2) 
Default = 0 



 

1. Decide alarm value 2 with 

 or 

 key (0~99999) 

2. Press 

 key enter data and return normal display 

 

 

Step  Parameter mark description  Parameter mark 

Operation manual 

Normal display 



 

Press

/SCALE key about 3 sec, into SCALE setting page

 



 

9-1 

SCALE (Scale) 
Default = 1.0000 



 

1. Decide scale with 

 or 

 key (0.0001~9.9999) 

2. Press 

 key enter data and return normal display 

 

 

Appendix  Error Mark Description 

Error Mark 

Analyze & Description 



 



 

EEPROM error detect 



 

1.External interference when EEPROM read/write 
2.EEPROM write over 100000 times(guarantee 10 years) 
Please power reset, if still display E-00, doing following step: 
1.

 

E-00 & No display for inquire reset EEPROM 

2.

 

Decide Yes with 

 key, press 

 key return normal display 

3

.

 

EEPROM has reset, Please follow step 1~9 setting again

 

 
 
 
 
 
 

Summary of Contents for MC48 Series

Page 1: ...Contact input NPN Sensor input NPN 5V 12V Inside jumper illustrates Key Introduce Operation Manual Key Function 1 In normal display The key function is call out setting group 2 In parameter setting p...

Page 2: ...1 DP Decimal Point Default 0 1 Decide decimal point position with key 0 4 2 Press key enter data and into TYPE setting page 4 2 TYPE Type Default 1U2G 1 Decide input type with key 1U2G 1G2U 1D2G 1G2D...

Page 3: ...d rate with key 38400 19200 9600 4800 2400 2 Press key enter data and into PARI setting page 7 3 PARI Communication Parity Check Default n 8 2 1 Decide Parity Check with key n 8 2 n 8 1 even odd 2 Pre...

Page 4: ...a t e i n p u t I N A P r o h i b i t g a t e i n p u t I N B C o u n ti n p u t U P D O W NT y p e 1 U 2 D 1 P 2 D 1 A 2 B x 4m o d e 0 C o u n t v a l u e 1 2 0 3 I N A H L I N B H L 4 5 I N A H L I...

Page 5: ...he OUT1 one shot output time has elapsed The output repeat OUT1 one shot operation OUT2 self holding output turns OFF after the OUT1 one shot output time The OUT2 one shot output time is indepen dent...

Page 6: ...lding output turns OFF after the OUT1 one shot output time The OUT2 one shot output time is independent of OUT1 Note 1 Self holding output One shot output Self holding output or One shot output 2 When...

Page 7: ...g Output Span Adjust Input Range E891 176F 5999 5999 R W 000D CODE Pass Code Input Range 00000000 0001869F 0 99999 high word R W 000E Pass Code Input Range 00000000 0001869F 0 99999 low word R W 000F...

Reviews: