Key Function

 

1.In normal display, The key function is call out adjustment display scale page 
2.Into parameter setting page, the parameter mark & data is alternate display,If need modify data can 

press 

 key into setting procedure, The display is lock parameter data, this time must let off key 

about 0.2 sec, press again, the parameter data will increment. (Key Response about 0.2 sec). If the 
setting value have negative,Shift cursor(twinkle express) to the leftest and Press

 key

 can positive 

/

 

negative number alternate display 

&

Key Function 

1.In setting group or setting page press 

&

 key return normal display, but if in setting page the 

modify data will be lost   

No Key in anything 

1.In setting group or setting page no key in anything about 2 minutes, return normal display, but if in 

Setting page the modify data will be lost 

 

Step  Parameter mark description  Parameter mark 

Operation manual 

Normal display 



 

Press 

/FUNC key into P.COD

E setting page 



 

P.CODE(Pass code input page) 
 



 

1.Key in 5 digit pass code with 

 or 

 key 

2.Press 

 key, the pass code is right into setting group, otherwise 

return normal display 

SYS(System setting group) 



 

ROP(Alarm setting group) 



 

AOP(Analog output setting           
group) 



 

DOP(Communication setting 
group) 



 

1.

 

Select setting group with 

 key

 

2.

 

Press 

 key into setting page of selection setting group 

 

 

SYS(System setting group) 



 

1.Press 

 key decide SYS setting group , press 

 key into DP setting 

page 



 

4-1 

DP(Decimal Point) 
Default = 0 

 

1.

 

Decide decimal point position with 

 key (0~4) 

2.

 

Press 

 key enter data and into TYPE setting page 



 

4-2 

TYPE(Type) 
Default = 1U2G 



 

1.Decide input type with 

 key (1U2G,1G2U,1D2G,1G2D 

,1U2D,1P2D,1A2B) 

2. Press 

 key enter data and into CNTS setting page 



 

4-3 

CNTS(Count Rates Select) 
Default = 50KHZ 



 

1.Decide Count Rates Select with 

 key (50HZ,50KHZ) 

2. Press 

 key enter data and into P.OFF.M setting page 

 



 

4-4 

P.OFF.M(Power Off Mode) 
Default = RESET 



 

1.Decide Power Off Mode with 

 key (RESET or MEMOR) 

2. Press 

 key enter data and into CODE setting page 

Note:RESET(Power Off Reset):Count value and Alarm is reset 
      MEMOR(Power Off Memory) :Count value and Alarm is save 



 

4-5 

CODE(Pass Code) 
Default = 0 



 

1.Decide pass code with 

 or 

 key (0~99999) 

2. Press 

 key enter data and into LOCK setting page 

 



 

4-6 

LOCK(Panel Lock) 
Default = NO 



 

1. Decide panel lock with 

 key(NO or YES) 

2. Press 

 key enter data and return SYS setting group 

 

ROP( Alarm setting group) 



 

1.Press 

 key decide ROP setting group, press 

 key into OP.MODE 

setting page 



 

5-1 

OP.MODE(Output Mode ) 
Default = N 
 

 

1. Decide output mode with 

 key (N,F,R,Q,C,P,K) 

2. Press 

 key enter data and into ACT1.T setting page 

 



 

5-2 

ACT1.T(Active 1 Time ) 
Default = 0 



 

1.Decide Active 1 Time with 

 or 

 key (0.0~99.9)sec. 

2. Press 

 key enter data and into ACT2.T setting page 

3.ACT1.T=0 sec. is self-holding output 1 

.ACT1.T=0.1~99.9 sec. is one-shot output 1 

Note:When :OP.MODE=N, ACT1.T = 0 sec. 



 

5-3 

ACT2.T(Active 2 Time ) 
Default = 0 



 

1. Decide Active 2 Time with 

 or 

 key (0.0~99.9)sec. 

2. Press 

 key enter data and return ROP setting group 

3. ACT2.T=0 sec. is self-holding output 2 

ACT2.T=0.1~99.9 sec. is one-shot output 2 

Summary of Contents for MC48 Series

Page 1: ...Contact input NPN Sensor input NPN 5V 12V Inside jumper illustrates Key Introduce Operation Manual Key Function 1 In normal display The key function is call out setting group 2 In parameter setting p...

Page 2: ...1 DP Decimal Point Default 0 1 Decide decimal point position with key 0 4 2 Press key enter data and into TYPE setting page 4 2 TYPE Type Default 1U2G 1 Decide input type with key 1U2G 1G2U 1D2G 1G2D...

Page 3: ...d rate with key 38400 19200 9600 4800 2400 2 Press key enter data and into PARI setting page 7 3 PARI Communication Parity Check Default n 8 2 1 Decide Parity Check with key n 8 2 n 8 1 even odd 2 Pre...

Page 4: ...a t e i n p u t I N A P r o h i b i t g a t e i n p u t I N B C o u n ti n p u t U P D O W NT y p e 1 U 2 D 1 P 2 D 1 A 2 B x 4m o d e 0 C o u n t v a l u e 1 2 0 3 I N A H L I N B H L 4 5 I N A H L I...

Page 5: ...he OUT1 one shot output time has elapsed The output repeat OUT1 one shot operation OUT2 self holding output turns OFF after the OUT1 one shot output time The OUT2 one shot output time is indepen dent...

Page 6: ...lding output turns OFF after the OUT1 one shot output time The OUT2 one shot output time is independent of OUT1 Note 1 Self holding output One shot output Self holding output or One shot output 2 When...

Page 7: ...g Output Span Adjust Input Range E891 176F 5999 5999 R W 000D CODE Pass Code Input Range 00000000 0001869F 0 99999 high word R W 000E Pass Code Input Range 00000000 0001869F 0 99999 low word R W 000F...

Reviews: