background image

IV. TROUBLESHOOTING

The primary reasons for inaccuracy or malfunction 

are low batteries, incorrect calibration, overload or 

operating on an unstable surface. Please keep this in 

mind and maintain and operate your scale properly. 

This scale is a precise instrument and must be 

handled with the utmost care and caution.

[Display]

Elimination of errors

Nothing, Battery-Symbol, [lo] or [88888] 

Change the batteries.

[OUE2]  

Recalibrate the scale as shown above.

[EEEEE] 

You are overloading the scale. Remove the 

excessive load immediately!

[LLLLL] 

The delicate weighing load cells have 

been damaged by misusing the scale 

(i.e. it was shocked, dropped or    

overloaded). You can try recalibrating the 

scale. If the load cell has not been 

damaged too much it will work  

 

again after recalibration.

[UNST]  

Use the scale in a more stable position