7
SYSTEM SETUP FOR OPERATION
WHEN CONNECTING THE HEADER
EACH SYSTEM IS DESIGNED SPECIFICALLY FOR THE INTENDED COMBINE TO
BE USED. DO NOT CONNECT SYSTEM TO A DIFFERENT COMBINE WITHOUT
CONSULTING TEMP FARM EQUIPMENT FOR APPROVAL. DRIVELINE
OVERSPEED COULD OCCUR
CONNECTING THE PTO
Ensure the feeder house drive splines are free debris and
covered in a light coat of grease.
Remove telescoping PTO shaft from storage hanger and connect
to feeder house shaft. Verify that the quick-attach collar fully
locks. Secure shield safety chain to feeder house.
ELECTRICAL CONNECTIONS
There is a single connection to be made between the combine
and AirBar system. Locate the 4-pin connector on the header
harness and connect to mating connector on feeder house.
WHEN DISCONNECTING THE HEADER
DISCONNECTING THE PTO
Disconnect telescoping PTO shaft from the feeder house shaft.
Place shaft in the storage hanger.
DO NOT LEAVE PTO SHAFT CONNECTED TO THE COMBINE. PERSONAL
INJURY OR MACHINE DAMAGE MAY OCCUR IF FEEDER HOUSE IS ENGAGED.
ELECTRICAL CONNECTIONS
Disconnect the 4-pin connector joining the combine to the
header. Secure both ends of the harness to avoid damage when
the system is not in use.