Install the 2 pieces magnetic switch to the door/window edge and frame; keep them close when the 
door/window is closed.

 Hard wiring to 12V low voltage magnetic switch is NOT needed. 

 

Air Curtain

Dedicated 2 wires (12V DC) for 

the magnetic switch

M

M

Install the 2 pieces magnetic 

switch  close together

Door/window

Door/window 

frame

Power cord (110V AC)

 

The air curtain should be installed indoor, consult with your electrical professional for 
electrical hard wiring connection. 
 

 

8. OPERATING INSTRUCTIONS                                                                          

 
8.1 Connect power (110V 60Hz) to the unit. 
8.2 Press the switch to the left or right to turn on the unit. [L] - Low speed, [H] - High speed. 
8.3 Adjust the air deflector to slightly outward at about 10 to 15 degrees to obtain optimum effect. 
 

9. MAINTENANCE AND CLEANING                                                                       

 

WARNING: 
 

A.  Any service is to be performed only by qualified personnel who are familiar with local 

codes and regulations and are experienced with this type of product.   

B.  Always unplug or disconnect the appliance from the power supply before servicing or 

cleaning the unit. 

C.  Never use petrol, benzene, thinners or any other such chemicals for cleaning the unit. 
D.  Don’t allow water or any liquid to enter the motor. 

 
9.1. Use the unit at the rated voltage and frequency indicated on the rating label. 
9.2. Disconnect power source before unit installation or maintenance service. 

9.3. Routine maintenance must be done every year. 

9.4. Plastic parts should be cleaned with mild soap water, thoroughly remove soap film with a 

clean damp cloth. 

9.5. Wipe the exterior surfaces of the fan with a moistened cloth with a solution of mild detergent 

and water. 

9.6. Dry the case with a soft dry cloth before operating the unit. 
 
 

10. SUPPORT AND CONTACT 

 
Contact your local seller for exchange or repair. 
Visit www.awoco.com for most updated information.   
Email to [email protected] for technical support and sales activity. 

Summary of Contents for FM-3509-L/Y

Page 1: ...FM 3509 L Y FM 3510 L Y FM 3512 L Y FM 3515 L Y 2 Speeds with Magnetic Switch Thanks for purchasing this Air Curtain PLEASE READ AND SAVE THESE INSTRUCTIONS Strongly recommend to test the unit before installation for any defective or damage during shipment ...

Page 2: ...r and maintenance operations can only be performed by qualified personnel F Verify and ensure the rated voltage and frequency please refer to the rating label of the air curtain is in compliance with the mains supply CONTENTS 1 PRODUCT INTRODUCTIONS 1 2 INSTALLATION DIMENSIONS 2 3 INSTALLATION CAUTIONS 3 4 INSTALLATION INSTRUCTIONS 4 5 TECHNICAL PARAMETER 5 6 WIRING DIAGRAM 6 7 OPTIONAL MAGNETIC D...

Page 3: ... are subjected to change without notice due to product development MODEL Max Entry Opening A B C D E F G H I FM 3509 L Y 38 35 43 27 36 2 91 3 94 8 46 9 06 4 84 FM 3510 L Y 42 42 00 27 36 FM 3512 L Y 50 47 24 38 98 11 61 FM 3515 L Y 62 59 06 50 59 19 84 ...

Page 4: ... loose or shake and make noise 3 2 Please install the unit inside the room 3 3 Install the unit between 7 feet to 8 feet from the ground ATENCIÓN Instalar la unidad entre los 7 a 9 pies desde del suelo 3 4 When the entrance is wider than the unit it is recommended to install two or more units in parallel In this case provide 20 40mm gaps between the units 3 5 Don t allow gaps between the unit and ...

Page 5: ...he washers and nuts as the Fig shows 4 1 4 Hang the main body onto the upper end of the mounting plate and then tighten the bottom fixing screws back to the mounting plate B Installing on the wooden wall Note make sure the screws are secured in the wood attach an extra wood frame to the wall if needed 4 2 1 Refer to step 4 1 1 and determine the mounting location then securely mount the mounting pl...

Page 6: ...usted in vertical direction according to need but the max distance is 100mm 4 3 4 Hang the main body onto the upper end of the mounting plate and then tie the bottom fixing screws back to the mounting plate 5 TECHNICAL PARAMETER Model No Voltage V Hz Power W Max air velocity FPM Air volume CFM Noise level dB Net weight Lb H L H L H L H L FM 3509 L Y 120V 60Hz 300 270 3150 2559 907 742 52 49 28 7 F...

Page 7: ...LOW 7 OPTIONAL MAGNETIC DOOR MICRO SWITCH INSTALLATION This air curtain comes with a magnetic door switch contact seller or Awoco if you are missing a magnetic switch The dedicated 2 wires Yellow are to connect to the magnetic switch Note Keep the 2 wires connected closed if the magnetic switch is not used Connect the magnetic door switch Cut the dedicated 2 wires nut and connect the wires to the ...

Page 8: ...el who are familiar with local codes and regulations and are experienced with this type of product B Always unplug or disconnect the appliance from the power supply before servicing or cleaning the unit C Never use petrol benzene thinners or any other such chemicals for cleaning the unit D Don t allow water or any liquid to enter the motor 9 1 Use the unit at the rated voltage and frequency indica...

Reviews: