 Remove the electric cover (

4

) fixed with screws (

3

).

Applicable to the H version: A sensor is attached to the electric cover. Remove the cover carefully so as not to damage the wiring harness connecting the sensor to 
the controller.

 

 Route the power cord in double insulation through the rubber grommet (

10

). Insert a sufficient length of the cord so that the wires can be connected to the power

terminals.

Before mounting the fan: remove all foreign objects from its inside; check manually that the fan rotor moves freely; check that there is room for opening the 
non-return valve baffle (9) located at the outlet of the bathroom extractor fan;
It is recommended to connect the fan to the duct using a flexible pipe connection!

 Place the fan housing (

8

) and the mounting pins in the previously drilled holes.

ATTENTION: The fan must be mounted so that the electrical compartment is at the top.

 Mount the fan to the substructure by driving the screws into mounting pins through the mounting holes (

11

).

 Remove the outer insulation from the power cord and remove the 4 mm of insulation from the wires.

 Arrange the power cord and connect according to the electrical wiring diagram applicable to the model installed.

Applicable to the T and H version:

 Insert the cores of the power cord into the corresponding holes of the terminal strip. For ease of use, lift the levers on the clamps. 

 Verify the tightness of the cable cores in the terminals.

 Check if the fan is firmly installed and correctly wired.

Applicable to the T and H version:

 Set the stop delay time and the humidity sensor sensitivity level using the potentiometer knobs on the controller (

7

).

 Check the tightness of the power cord. 

   - The power cord must be secured so that in case of flooding there is no ingress of water to live parts.

 Place the electric cover (

4

) and secure with the screws (

3

).

 Slide the handles of the front panel (

1

) into the holes of the impeller cover (

2

). 

 Place the front panel and the impeller cover on the front of the fan in a counterclockwise direction by approx. 5°. Then turn clockwise until the latches are locked.

                          ATTENTION! A rotating impeller can crush your fingers! 
                          It is forbidden to start the fan without a protective mesh against touching the moving parts!

15

EN

Summary of Contents for WPA110

Page 1: ...ipment The Operating Manual specifies important technical information and instructions for the operating safety of the fan Carefully read the installation instructions in the Operating Manual Keep the...

Page 2: ...e capable of breaking live voltage contact on all switching poles to fully isolate the fan from power during Category III overvoltage conditions in accordance to applicable electrical engineering regu...

Page 3: ...exhaust fan can be installed in indoor moisture Zone II in accordance with IEC 60364 7 701 provided that the following requirements from the air exhaust fan manufacturer are complied with 1 the corre...

Page 4: ...rical wiring diagram see Fig 2 The air exhaust fan is started and stopped by a separate on off switch installed in the power supply line of the building and not included with the product Timer part in...

Page 5: ...ching off the light or the on off switch the air exhaust fan will stop after the stop delay time set with the potentiometer if the humidity level in the room is below the level preset on the potentiom...

Page 6: ...ion from the power cord and remove the 4 mm of insulation from the wires Arrange the power cord and connect according to the electrical wiring diagram applicable to the model installed Applicable to t...

Page 7: ...ilure to provide the required safety equipment Electrical connections Electrical connections and commissioning of the fan shall only be completed by qualified professional electricians Always follow t...

Page 8: ...aggressive paint solvents Do not clean with a high pressure cleaner or strong jets of water Clean carefully to prevent water from entering the motor or the terminal box Always keep the guard grille a...

Page 9: ...r is required to return the product which has become WEEE to a WEEE collection unit The operators of WEEE collection units including local WEEE locations product resellers and other WEEE collection lo...

Page 10: ...L N N L L N N L SL L N SL N L Rys 2 Fig 2 2 Obr 2 Rys 3 Fig 3 3 Obr 3 Rys 4 Fig 4 4 Obr 4 1 2 3 4 8 7 6 5 10 11 9 Rys 1 Fig 1 1 Obr 1 47...

Page 11: ...Mi sk Mazowiecki Stojad a ul Warszawska 99 Poland Tel 48 25 758 52 52 48 25 758 93 92 fax 48 25 758 14 62 e mail info awenta pl www awenta pl INDEX 1 2 A B X Y W Z WPA110 100 110 152 152 180 180 132 8...

Reviews: