- flammable contaminants, including gas, vapours, mists or particulates which may form explosive mixtures with air.

  The control system must prevent extremely frequent power cycling.

Transport and storage

  Keep the air exhaust fans in their original packaging in a dry, sheltered room.

  The transport and storage ambient temperature limits are -20 °C to +40 °C.

  Protect against impact and shocks. Transport the air exhaust fan in its original packaging.

  If the storage time exceeds 1 year, the motor bearings of the air exhaust fan must be tested by turning the fan rotor by hand before installation. The fan rotor must

run smoothly.

  Dispose of the air exhaust fan at the end of its operating life strictly in accordance with environmental protection and waste management laws.

  Should it occur, damage caused by improper transport, handling, storage or commissioning will be demonstrated and is not on warranty.

ACCESSORIES
Available optional accessories:

Terminal block (standard version, no part index suffix). 

Connect the air exhaust fan with the terminal block as shown in the electrical wiring diagram, see Fig. 2.

The air exhaust fan is started and stopped by a separate on/off switch installed in the power supply line of the building (and not included with the product).

Timer (part index suffix “T”). 

Connect the fan with the timer (a switch-off delay) as shown in the electrical wiring diagram, see Fig. 3.

 

The stop delay time can be set with a potentiometer knob on the electronic module of the stop delay timer. The minimum stop delay time is set at 3 min. with the 

potentiometer knob rotated counter-clockwise to stop. Turn the potentiometer knob clockwise to set a longer stop delay time accordingly. The maximum stop delay 

time setting is 30 min. The stop delay time is adjusted in infinite increments. The stop delay time is counted down from the moment when the signal at the “SL” terminal 

disappears caused by switching off the lighting or the on/off switch to which the appliance is connected. Depending on the setting of the “DELAY” slider on the 

controller, the fan will start operating when voltage is detected on the “SL” terminal or after 2 minutes after voltage is detected.

Humidity sensor (part name suffix “H”). 

Models equipped with humidity sensor (hygrostat) and timer should be connected according to the connection diagram 

in Fig. 3. or Fig. 4.

13

EN

Summary of Contents for WPA110

Page 1: ...ipment The Operating Manual specifies important technical information and instructions for the operating safety of the fan Carefully read the installation instructions in the Operating Manual Keep the...

Page 2: ...e capable of breaking live voltage contact on all switching poles to fully isolate the fan from power during Category III overvoltage conditions in accordance to applicable electrical engineering regu...

Page 3: ...exhaust fan can be installed in indoor moisture Zone II in accordance with IEC 60364 7 701 provided that the following requirements from the air exhaust fan manufacturer are complied with 1 the corre...

Page 4: ...rical wiring diagram see Fig 2 The air exhaust fan is started and stopped by a separate on off switch installed in the power supply line of the building and not included with the product Timer part in...

Page 5: ...ching off the light or the on off switch the air exhaust fan will stop after the stop delay time set with the potentiometer if the humidity level in the room is below the level preset on the potentiom...

Page 6: ...ion from the power cord and remove the 4 mm of insulation from the wires Arrange the power cord and connect according to the electrical wiring diagram applicable to the model installed Applicable to t...

Page 7: ...ilure to provide the required safety equipment Electrical connections Electrical connections and commissioning of the fan shall only be completed by qualified professional electricians Always follow t...

Page 8: ...aggressive paint solvents Do not clean with a high pressure cleaner or strong jets of water Clean carefully to prevent water from entering the motor or the terminal box Always keep the guard grille a...

Page 9: ...r is required to return the product which has become WEEE to a WEEE collection unit The operators of WEEE collection units including local WEEE locations product resellers and other WEEE collection lo...

Page 10: ...L N N L L N N L SL L N SL N L Rys 2 Fig 2 2 Obr 2 Rys 3 Fig 3 3 Obr 3 Rys 4 Fig 4 4 Obr 4 1 2 3 4 8 7 6 5 10 11 9 Rys 1 Fig 1 1 Obr 1 47...

Page 11: ...Mi sk Mazowiecki Stojad a ul Warszawska 99 Poland Tel 48 25 758 52 52 48 25 758 93 92 fax 48 25 758 14 62 e mail info awenta pl www awenta pl INDEX 1 2 A B X Y W Z WPA110 100 110 152 152 180 180 132 8...

Reviews: