Awenta WPA110 Operating Manual Download Page 1

Danger!

Electrocution hazard: high voltage!

OPERATING MANUAL 

WPA

IMPORTANT NOTICE

Please read the Operating Manual carefully before attempting to install or service the air exhaust fan! 

AWENTA shall not be liable for any 

damage resulting from incorrect operation, non-intended use or unauthorized repair or modifications of the product.

The Operating Manual and the installation instructions contained in it are an essential part of the product equipment. The Operating 

Manual specifies important technical information and instructions for the operating safety of the fan. Carefully read the installation 

instructions in the Operating Manual. Keep the Operating Manual available for future reference. A copy of the Operating Manual can be 

downloaded from 

www.awenta.pl

 

Warnings

The following safety symbols show important safety information. Follow all safety regulations and the safety symbols shown in the 

Operating Manual to avoid injury and hazards.

Safety precautions:

• 

This product can be used by children at least 8 years old, by people with impaired physical

Caution – rotating elements!

10

EN

Summary of Contents for WPA110

Page 1: ...ipment The Operating Manual specifies important technical information and instructions for the operating safety of the fan Carefully read the installation instructions in the Operating Manual Keep the...

Page 2: ...e capable of breaking live voltage contact on all switching poles to fully isolate the fan from power during Category III overvoltage conditions in accordance to applicable electrical engineering regu...

Page 3: ...exhaust fan can be installed in indoor moisture Zone II in accordance with IEC 60364 7 701 provided that the following requirements from the air exhaust fan manufacturer are complied with 1 the corre...

Page 4: ...rical wiring diagram see Fig 2 The air exhaust fan is started and stopped by a separate on off switch installed in the power supply line of the building and not included with the product Timer part in...

Page 5: ...ching off the light or the on off switch the air exhaust fan will stop after the stop delay time set with the potentiometer if the humidity level in the room is below the level preset on the potentiom...

Page 6: ...ion from the power cord and remove the 4 mm of insulation from the wires Arrange the power cord and connect according to the electrical wiring diagram applicable to the model installed Applicable to t...

Page 7: ...ilure to provide the required safety equipment Electrical connections Electrical connections and commissioning of the fan shall only be completed by qualified professional electricians Always follow t...

Page 8: ...aggressive paint solvents Do not clean with a high pressure cleaner or strong jets of water Clean carefully to prevent water from entering the motor or the terminal box Always keep the guard grille a...

Page 9: ...r is required to return the product which has become WEEE to a WEEE collection unit The operators of WEEE collection units including local WEEE locations product resellers and other WEEE collection lo...

Page 10: ...L N N L L N N L SL L N SL N L Rys 2 Fig 2 2 Obr 2 Rys 3 Fig 3 3 Obr 3 Rys 4 Fig 4 4 Obr 4 1 2 3 4 8 7 6 5 10 11 9 Rys 1 Fig 1 1 Obr 1 47...

Page 11: ...Mi sk Mazowiecki Stojad a ul Warszawska 99 Poland Tel 48 25 758 52 52 48 25 758 93 92 fax 48 25 758 14 62 e mail info awenta pl www awenta pl INDEX 1 2 A B X Y W Z WPA110 100 110 152 152 180 180 132 8...

Reviews: