![Awaiba Orion USB3 Manual Download Page 8](http://html.mh-extra.com/html/awaiba/orion-usb3/orion-usb3_manual_3035178008.webp)
Orion USB3 Evaluation Kit
3.3 Auxiliary pixel settings
This sensor has the unique feature of have two pixel sizes option available for the user. Basically the
user can choose between a small photo diode pixel 10 um x 10 um, and larger one with 10 um x 200
um.
Reg 0x08
Reg 0x02
Large Pixel
10 um x 200 um
Bit 7 = 0
CVC Gain = 1x
Bit 3 = 1
Smaller Pixel
10 um x 10 um
Bit 7 = 1
CVC Gain = 11x
Bit 3 = 0
Table 3: Pixel size configuration
3.4 External Trigger Input
As an example of the signal that can be connected to the external trigger pin, please use a pulse
generator with 970Hz and make sure that between each pulse you have 1ms.
Please change the FPGA register 0, Sensor Operation Control to 0x07.
Date: 30/03/16
Version 1.0.4
Page: 8/16