Avue G40 User Manual Download Page 6

4.INSTALLATION

4.INSTALLATION

The speed dome series provide an integrated termination switch. It should be 
turned ON on the dome serving as the last device. If a controller keyboard is 
used, you also need to turn the termination ON on the keyboard. Please refer to 
the keyboard’s manual for details.

RS485 Termination

Devices using RS485 control are usually connected in daisy-chain which 
reqiuers termination with 120

Ω

 resistor on both ends. The following graphic 

illustrates the connection methods. Please note that a daisy-chain connection 
type shall not exceed 7 meters.

120

Ω

R

esistor

Device 2

Device 3

Device 1

120

Ω

R

esistor

RS 485+

RS 485-

Some products may not be available in your country, please contact our distributor for more details

Some products may not be available in your country, please contact our distributor for more details

7

8

RS 485+

RS 485-

Termination on

Termination
on

Termination 
off

Termination 
off

Video Cable

Coaxial cable with 75  impedance with copper conductor at the center and shielded 
with  95% copper. The following table shows different cable types and their maximum 
length:

Ω

The values are for reference only. 
Depending on the qualiy tof the cable and 
environmental conditions the 
transmission distance might decrease.

RG 6 /U

Cable standard

RG 11 /U

229m / 750 ft

Max. Distance (m /ft )

305m/ 1000 ft

457m / 1500 ft

RG 59 /U

Star-Connection

The star-form connection is a popular way to connect different devices. It enables 
longer distance connection of different dome cameras. It is recommended to use 
RS485 distributor to ensure the telemetric data transmission:

The advantage of star-connection is 
that every channel can work 
independently and supports a cable 
length up to 1000 meters (depending on 
the  quality of the cable). In case more 
dome cameras are installed, the star-
connection can be extended with 
additional RS485 distributors.

Termination on

RS-485 
Distributor

RS485 cable
up to 1000m 
per channel

Termination
activated on
every end.

How to turn  termination ON on the Dome  

The termination switch is located on the rear side of the connection board. For 
turning it ON open theconnector board.

If the cable length is more than 400 m, it is recommended to use optional accessories, 
such as video amlifiersor twisted-pair video converters, to amplify the video signal.

Video Amplifier
(optional)

Real time DVR Center

(optional)

High Res Monitor
(optional)

Up to 750m, coaxial cable

Extend connection distance with
video amplifier

TP receiver
(optional)

Real time DVR Center

(optional)

High Res Monitor
(optional)

Up to 1200m, twisted pair or cat.5 cable

Extend connection distance with Twisted-Pair 
video converter

transmitter
(optional)

Optional bracket accessories

The speed dome can be equipped with various bracket accessories for indoor and 
outdoor installation. Please contact your distributor for further details.

Corner 
mount

Pole 
mount

Wall mount 

Ceilling 
mount

Wall
mount

Summary of Contents for G40

Page 1: ...User Manual English v1 03 Middle Speed Dome Camera Series ...

Page 2: ... BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE JUST QUALIFIED SERVICE PERSONNEL SHOULD SERIVICE THE PRODUCT This s...

Page 3: ...s this may damage the mechanic sturcture of the appliance and voids the warranty Do not touch the cover with bare hands or any objects These will scratch the surface and negatively affect the image qulaity 2 FEATURES The middle speed dome camera series are designed for video surveillance applications The integrated motorized pan tilt mechanic allows users to maneuver the camera to any position 360...

Page 4: ...g protection and grounding of the device should be considered Please refer to the industrial saftey regulations of your country Grounding of the appliance should include anti interference and fulfill the safety requirements Do not connect the ground with short circuited or other high voltage electric networks The resistance of down conductor should not exceed 4 Ohm and its thickness should be at l...

Page 5: ...logy Depending on the cable type and baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 400m 4800 bps 1700m 9600 bps 19200 bps Baud Rate Max Distance Due the environmental interferences such as eletromagnetic and induction fields or number of connected appliance on the RS485 bus the transmission ...

Page 6: ...Star Connection The star form connection is a popular way to connect different devices It enables longer distance connection of different dome cameras It is recommended to use RS485 distributor to ensure the telemetric data transmission The advantage of star connection is that every channel can work independently and supports a cable length up to 1000 meters depending on the quality of the cable I...

Page 7: ...aud rate Address ID and protocol of both keyboard and the dome are correctly configurated For further details on operating the PTZ please refer to the user s manual of the keyboard OSD Menu The dome camera are equipped with the new OSD Menu function All operational functions and camera related settings can be controlled here In order to use the OSD function a telemetric controller device such as k...

Page 8: ...P R E S E T C L E A R P R E S E T E D I T P R E S E T L A B E L B A C K E X I T L A B E L P R E S E T 0 1 B A C K E X I T E D I T P R E S E T L A B E L L A B E L A U T O S C A N B A C K E X I T EDIT SCAN LABEL L A B E L P A T T E R N 1 B A C K E X I T EDIT PATTERN LABEL L A B E L Z O N E 1 B A C K E X I T EDIT ZONE LABEL L A B E L S P E E D D O M E B A C K E X I T 1 00 E D I T D O M E L A B E L D ...

Page 9: ...CK EXIT 6 OSD Camera Setting ADVANCE SETTING AE MODE AUTO SHUTTER N A IRIS N A BRIGHT N A WB MODE AUTO R GAIN N A B GAIN N A BACK EXIT Advanced Setting Under the advanced setting you can make improvements tothe image quality depending on different environmental conditions AE MODE Auto Exposure mode Depends on the light condition in the surveillance area you can set the AE in different modes and ad...

Page 10: ...P R E S E T C L E A R P R E S E T E D I T P R E S E T L A B E L B A C K EXIT Scan The SCAN function moves the PTZ between 2 predefined points with constant speed The following parameters can be set SCAN NUMBER Supports up to 4 scans SCAN SPEED Cruising speed between the points SET LEFT LIMIT Defines the left point SET RIGHT LIMIT Defines the right point CLEAR SCAN Deletes the scan setting RUN SCAN...

Page 11: ...a modules up to 24 masking areas except the 45 series provides only 8 LG CNB Camera modules no masking function WINDOW NUMBER Mask number EDIT WINDOW Edit position of the mask using the keyboard s joystick Presse IRIS OPEN to save ENABLE WINDOW Shows the mask on the screen CLEAR WINDOW Deletes the mask WINDOW BLANKING WINDOW NUMBER 01 EDIT WINDOW ENABLE WINDOW OFF CLEAR WINDOW BACK EXIT 7 PROTOCOL...

Page 12: ...1 1 1 0 0 0 0 0 41 1 0 0 1 0 1 0 0 ID ID 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 34 Some products may not be available in your country please contact our distributor for more details 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 101 100 99 98 96 97 95 94 93 92 91 90 89 87 88 86 85 84 83 82 72 81 80 79 78 77 76 75 74 ...

Page 13: ... 0 0 0 1 0 1 1 0 1 0 0 0 1 1 0 0 1 0 0 1 0 1 0 1 1 0 0 0 1 1 1 0 1 0 0 1 0 1 1 1 1 0 0 0 1 1 0 1 1 0 0 1 0 1 0 0 0 1 0 0 1 1 1 1 1 0 0 1 0 1 1 0 0 1 0 0 1 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 1 0 0 1 0 1 0 1 1 1 0 1 0 0 1 1 ID ID Switchnumber Sw1 Switchnumber Sw1 Some products may not be available in your country please contact our distributor for more details 237 236 235 234 233 255 254 253 252 251 ...

Page 14: ...ua Auto Slow Shutter LOW MEDIUN HIGH MANUAL OFF CVBS 1 0Vp p 75Ω 0 100 per Sec Shutter Speed 1 to 1 10 000 Sec 1 3 to 1 10 000 Sec Focus White Balance Auto Manual Auto Manual ATW Indoor Outdoor One Push WB Manual WB Viewing Angle Image Sensor 1 4 inch super HAD color CCD Model Signal Format Scanning PAL NTSC 2 1 Interlace H Resolution 550 TV Lines Min Color 680 TV Lines Min B W H Appr 55 5 Wide to...

Reviews: