Avtron SMARTach III AV850 Manual Download Page 2

AV850 2

Spare sensors, rotors, through-shaft cover 

plates, and shaft grounding kits can be 

ordered separately. (See Tables 2, 3, and 4)

Cam screw rotors patented.

TABLE 1

TABLE 2

AV850 PART NUMBERS AND AVAILABLE OPTIONS

Model Rotor  

Style

Shaft  

Size

Inboard & Outboard 

Cover Plates

Left Module

Right Module

Connector 

Options

Modifications

Line Driver

PPR

Line Driver

PPR

AV850

X- none

D-  no inboard, domed  

  outboard cover  

 plate

B-  inboard, thru out- 

 board

>

F-  no inboard, flat  

 outboard

N- inboard, flat out- 

 board

>

T-  no inboard, thru  

 outboard

>

X- none

6-  5-24V in/out  

 (7272)

8-  5-24V in/out

 (HX)

9-  5-24V in,  

  5V out (7272)

X- none

6-  5-24V in/out  

 (7272)

8-  5-24V in/out

 (HX)

9-  5-24V in,  

  5V out (7272)

000- none

003- Include analog 

      signal converter 

      (K661) 

004- Super sensor 

        shielding 

4xx-  Special PPR 

        (see chart)

704-  Large Motor 

        Stator 

        Adapter

+

X- none

F- 60 

C- 64

G- 100

H- 120

A- 128

L- 240

N- 256

P- 300

E- 360

B- 480

Q- 500

R- 512

S- 600

U- 720

V- 900

J- 960

W- 1000 

Y- 1024

Z- 1200

2- 1500

6- 1800

3- 2000

4- 2048

5- 2500

D- 4096

8- 4800

9- 5000

0-  special

X- none

F- 60 

C- 64

G- 100

H- 120

A- 128

L- 240

N- 256

P- 300

E- 360

B- 480

Q- 500

R- 512

S- 600

U- 720

V- 900

J- 960

W- 1000 

Y- 1024

Z- 1200

2- 1500

6- 1800

3- 2000

4- 2048

5- 2500

D- 4096

8- 4800

9- 5000

0-  special

Rotor Style

Shaft Size

T- Thru Shaft (Inch)

C- Thru Shaft, Cam Screw (Inch)

B- 0.625

A- 0.750

C- 0.875

E- 1.000

F- 1.125

H- 1.375

8- 1.500

J- 1.625

K- 1.750

L- 1.875

M- 2.000

N- 2.125

Q- 2.250

P- 2.375

R- 2.500

T- 2.625

S- 2.771

2- 2.875

U- 3.000

W- 3.250

Y- 3.375

Z- 3.421

V- 3.4375

3- 3.500

G- 3.750

4- 3.875

1- 4.000

7- 4.250

6- 4.500

B- Thru Shaft (Inch)

C- 1.250

A- 1.9375

B- 3.1250

M- Thru Shaft (mm)

E- 19mm

F- 30mm

J- 42mm

P- 60mm

T- 70mm

Z- 19mm 

4- 95mm

5- 100mm

8- 110mm

D- Thru Shaft (mm)

C- 17mm

E- 19mm

F- 30mm

J- 42mm

K- 45mm

P- 60mm

Q- 65mm

S- 70mm

Y- 180mm

2- 90mm

D- 93mm

E- End of Shaft 

H- End of Shaft for Grounding Kit

F-  1.125 GE CD180-320

N-  2.125 GE CD360

P-  2.375 GE CD400

Q-  2.250 GE CD444/505E

2-  2.875 GE CD500

9-  GE CD6000, 6100, 6200, 

  6700, 6800, & 6900

U- Universal with End of Shaft 

G- Universal with Grounding Kit 

Q- EOS Adapter for Stacked  

 Encoders

F-  1.125 GE CD180-320

N-  2.125 GE CD360

P-  2.375 GE CD400

2-  2.875 GE CD500

R-  GE CD507, 509

9-  GE CD6000, 6100, 6200,  

 

6700, 6800, & 6900

V-  GE CD4300, 4400,  

 

5400,6400 & 6500

+

W-  GE CD4500, 7500, 7600

+

Y-  GE CD4600, 4700, 8500,  

 

& 8600

+

Z-  GE CD680

+

4-  ABB 95mm

U-  Universal (Includes 1 Rotor  

 

and Shaft adapters for all 

 

motors except Q, R, Z & 4)

Q-  GE CD444/505E

+

K-Keyway Thru Shaft, Cam Screw (Inch)

E- 1.000

X- no rotor

X- no rotor

Connector Options

Mounted on Encoder Body

3' Cable

5' Flexible  

Conduit

Industrial  

Connector

5 pin MS

10 pin MS

Other

Industrial  

Connector

TwistLock

Other

P- Large, with 

       Plug

G- Large, 

     (Northstar

TM

  

 Pinout) 

 

  with Plug

1-  Small, (M3/M4 

     Pinout)

E

(M737 Pinout)

  

  without Plug

F- “E” with Plug

H

(M727 Pinout)  

 

without Plug

J- “H” with Plug

A-  without Plug

B-  with Plug

C-  with Plug & Flex.  

  Conduit Adapter

L-  with Right Angle Plug

K-  Condulet  

  with Leads

R-  Mini MS  

 TwistLock 

  with Plug

3-  6 Pin MS  

 connector 

 

  (M940 Pinout)

Z- Large,  

      with Plug

Q- Large,  

     with Plug on 

 Remote 

 

 Base, 

 

      18” cable

S-  Mini MS  

  without Plug

W-  Leads only

N-  Leads only

T-  Terminal box

+  Large motor stator adapter required if not previously installed.   > N/A for End of Shaft rotor styles.   

 Rotor Style “T” only.

AV5 Sensor

Model

Line Driver

 PPR

Connector Options

Modifications

AV5-

6

5-24V in/out (7272)

8

5-24V in/out (HX)

9

5-24V in, 5V out (7272)

See above list

000- none

004-  Super magnetic shielding

4xx-  Special PPR (see chart)

X- none

F- 60 

C- 64

G- 100

H- 120

A- 128

L- 240

N- 256

P- 300

E- 360

B- 480

Q- 500

R- 512

S- 600

U- 720

V- 900

J- 960

W- 1000 

Y- 1024

Z- 1200

2- 1500

6- 1800

3- 2000

4- 2048

5- 2500

D- 4096

8- 4800

9- 5000

0-  special

SPECIAL PPR OPTION CODES

4xx Code

PPR (Left)

PPR (Right)

4xx Code

PPR (Left)

PPR (Right)

4xx Code

PPR (Left)

PPR (Right)

401*

1270

None

408

1400

None

415

3000

None

402*

150

None

409*

30

None

416

3600

None

403*

50

None

410

None

6000

417

1250

None

404

None

16

411

12000

None

418

2400

2400

405

16

None

412

200

None

419

160

160

406

6000

None

413*

30

30

420

450

None

407

2800

None

414

1500

None

NOTE 

Special option 4xx selects an 

alternate PPR code  

definition. Example: PPR Code 

0, special option code  

401=1270 PPR (Left) / no right 

output.

Summary of Contents for SMARTach III AV850

Page 1: ...4 Install rotor as usual but gage location from the shield See Figure 3 The outer edge of the rotor may be damaged by scratches severe blows and strong magnetic fields GENERAL The Avtron Model AV850...

Page 2: ...Shaft G Universal with Grounding Kit Q EOS Adapter for Stacked Encoders F 1 125 GE CD180 320 N 2 125 GE CD360 P 2 375 GE CD400 2 2 875 GE CD500 R GE CD507 509 9 GE CD6000 6100 6200 6700 6800 6900 V GE...

Page 3: ...0 004 0 10mm Apply anti seize compound to the shaft CAUTION Do not strike the encoder or rotor at any time Damage will result and the warranty will be void At installation clean and remove paint and b...

Page 4: ...hase Wiring see wiring diagram Exchange either A with A in the phase A pair OR B with B in the phase B pair but NOT both 3 Apply power 4 Verify encoder feedback is correct using hand rotation of shaft...

Page 5: ...roubleshooting process if possible spin the encoder while replacing individual output connections This may make the ORANGE LED condition occur faster Once the shorted output s are located correct the...

Page 6: ...Temperature 40 to 100 C 0 100 condensing humidity Vibration 18 g s Shock 1 meter drop test LINE DRIVER OPTIONS SPECIFICATIONS Alarm not available on connector option G NorthstarTM compatible pinout E...

Page 7: ...OUT ALM RED BLUE GREEN BLACK ORANGE BROWN VIOLET OPTION OPTION OPTION OPTION T OPTION B E D A C F J 6 3 2 1 4 5 10 D B A F C NC NC B C E A D NC NC OPTION E F 6 3 2 1 4 NC NC 10 E D A F NC NC NC OPTION...

Page 8: ...POWER SUPPLY 115 VAC SINK 100 mA MAXIMUM WITHSTAND 50 V MAXIMUM REFERENCED TO COMMON ENCODER FUNCTIONAL DIAGRAM B A A B LINE DRIVER N K W A B C L P V X Z Example 2 Alarm Output Using Separate 24 VDC...

Page 9: ...2 2 3 0 2 4 3 A 3 C 4 1 5 1 3 B 3 C 3 T 5 1 9 0 3 B 3 T 0 0 5 3 A N A N 3 4 9 1 7 4 3 2 3 0 2 4 3 A A N A N 4 T 5 1 9 0 3 B 4 T 5 7 8 3 A N A N A N 4 2 3 0 2 4 3 A A N A N 6 T 5 1 9 0 3 B 6 T 0 0 5 4...

Page 10: ...0 MIN OPTION X SURFACE MOUNT CONNECTOR ONLY OPTION Z WITH MATING PLUG 0 53 13 5 0 41 10 5 1 20 30 5 4 31 109 5 1 574 40 0 2 13 54 0 3 228 82 0 3 70 94 0 0 18 4 5 0 217 5 50 4 Holes 36 50 927 0 MIN ON...

Page 11: ...DULE 0 53 13 5 3 83 97 3 4 66 118 4 OPTION K 2 80 71 1 3 06 11 7 1 53 38 9 OPTION A BULKHEAD CONNECTOR ONLY OPTION B WITH MATING PLUG CABLE GROMMET 1 97 50 0 3 67 93 2 Assembled 0 53 13 5 1 66 42 2 OP...