background image

AV56A 8

OPTION

“L” & “W”

OPTION

“P” & “Z”

SIGNAL CODING TABLE

BLACK

RED

GREEN

YELLOW

BLUE

GRAY

ORANGE

WHITE

BROWN

VIOLET

1

6

2

7

3

8

4

9

5

10

A

B

D

G

E

H

C

I

F

J

1

6

2

7

3

8

4

9

NC

NC

FOR DIFFERENTIAL APPLICATIONS

REF

SIGNAL

COM

+V

ØA

ØA–

ØB

ØB–

Z

Z–

+V out (alarm)

ALM

 

+5 TO +24 VOLTS

= MARKER

(SEE LINE 

DRIVER

OPTIONS)

SIGNAL CODING TABLE

RED

GREEN

BLACK

BROWN

VIOLET

6

2

1

5

10

D

F

NC

NC

D

F

NC

NC

B

D

A

5

10

6

2

1

NC

NC

OPTION

“P” & “Z”

SIGNAL CODING TABLE

RED

GREEN

BLUE

BLACK
BROWN

VIOLET

6

2

3

1
5

10

D

A

B

F

NC

NC

D

A

B

F

NC

NC

B

D

E

A
F

J

6

2

3

1

NC

NC

FOR SINGLE ENDED TWO PHASE APPLICATIONS

FOR SINGLE ENDED SINGLE PHASE APPLICATIONS

REF

SIGNAL

+V

ØA

ØB

COM

+V (out)

ALM

REF

SIGNAL

+V

SIG

COM

+V (out)

ALM

OPTION

“G” & “Q”

OPTION

“Y”

OPTION

“L” & “W”

OPTION

“G” & “Q”

OPTION

“Y”

OPTION

“P” & “Z”

OPTION

“L” & “W”

OPTION

“G” & “Q”

OPTION

“Y”

OPTION

“R” & “S”

F

D

A

H

B

J

C

K

NC

NC

OPTION

“R” & “S”

OPTION

“R” & “S”

OPTION

“A”,“B”,“C”,“D” 

OPTION

“A”,“B”,“C”,“D” 

OPTION

“A”,“B”,“C”,“D” 

F

D

A

H

B

I

C

J

NC

NC

OPTION

“L” & “W”

SIGNAL CODING TABLE

BLACK

RED

GREEN

YELLOW

BLUE

GRAY

ORANGE

WHITE

BROWN

VIOLET

7

2

1

3

4

5

6

8

NC

NC

1

2

3

4

5

6

7

8

NC

NC

FOR DIFFERENTIAL APPLICATIONS

REF

SIGNAL

COM

+V

ØA

ØA–

ØB

ØB–

Z

Z–

+V out (alarm)

ALM

 

+5 TO +24 VOLTS

= MARKER

(SEE LINE 

DRIVER

OPTIONS)

OPTION

“T”

OPTION

“U”

WIRING DIAGRAMS

For option “W”, unused outputs must be insulated to prevent  

accidental contact.
*NOTE: Single ended wiring not recommended for line driver 

option “8”

Summary of Contents for AV56A

Page 1: ...ption code below 9xx Special Cable Length xx length in feet Equipment Needed for Installation Provided Optional Not Provided AV56A Stator Housing Socket Hd Cap Screw 3 8 16 x 1 25 4 AV56A Rotor Socket...

Page 2: ...021 0 58mm Tolerance 0 015 0 38mm F Rotor Axial Tolerance 0 050 1 27mm ENVIRONMENTAL Solid cast aluminum stator and rotor Fully potted electronics protected against oil and water spray Use W cable opt...

Page 3: ...B at the use end of the wires b Differential 2 Phase Wiring see wiring diagram Exchange either A with A in the phase A pair OR B with B in the phase B pair but NOT both 3 Apply Power 4 Verify encoder...

Page 4: ...ler and do not use a heat gun Instead insert two M6 screws 25mm length into the Jack Screw Holes shown in Fig 2 Alternately tighten the screws to push the rotor away from the motor and remove it LARGE...

Page 5: ...7 MIN A ADD L SHAFT LENGTH REQ D FOR V RING 0 19 0 02 4 6 0 5 0 24 0 03 6 1 0 8 0 28 0 04 7 1 1 0 0 35 0 05 8 9 1 3 2 75 3 00 70 0 79 4 0 38 9 7 MIN 0 35 0 05 8 9 1 3 Add 0 22 5 6 for cover depth 3 00...

Page 6: ...CK N A A36521 TK A36523 TK 471970 1 875 1 8745 AVTR1 CL N A A36521 TL A36523 TL 471970 2 000 1 9995 AVTR1 CM N A A36521 TM A36523 TM 471971 2 125 2 1245 AVTR1 CN N A A36521 TN A36523 TN 471972 2 250...

Page 7: ...4mm DF AVTR1 DF N A A36522 MF A36524 MF 471964 28mm DG AVTR1 DG N A A36522 MG A36524 MG 471965 30mm DH AVTR1 DH N A A36522 MH A36524 MH 471966 32mm DT AVTR1 DT N A A36522 MT A36524 MT 471967 36mm DJ A...

Page 8: ...ICATIONS FOR SINGLE ENDED SINGLE PHASE APPLICATIONS REF SIGNAL V A B COM V out ALM REF SIGNAL V SIG COM V out ALM OPTION G Q OPTION Y OPTION L W OPTION G Q OPTION Y OPTION P Z OPTION L W OPTION G Q OP...

Page 9: ...0 mA MAXIMUM WITHSTAND 50 V MAXIMUM REFERENCED TO COMMON Q5 MMFT6661 ENCODER FUNCTIONAL DIAGRAM B A A B LINE DRIVER NOTE 1 CR8 L W P Z Example 2 Alarm Output Using Separate 24 VDC Power Supply and Rel...

Page 10: ...114 4016 DIA OPTIONAL COVER FOR EXTENDED SHAFT MOTORS 1 97 50 0 2 74 69 9 OPTIONAL ISOLATED DUAL OUTPUT 1 2 14 NPT OPTION P G PLUG IN INDUSTRIAL CONNECTOR ADDITIONAL OPTIONS SHOWN 0 410 10 41 DIA 4 H...