background image

AV56A 7

THIN-LINE II & III Spare Parts  

(AV56A/AV56S/AV67/AV85/AV115 Only) 

Metric Sizes

Shaft  

Size 

Rotors AV56A, AV67,  

AV85, AV115

Thru-Shaft Covers

Option 

Code

CAM 

Screw

Set Screw

AV56, AV56S, 

AV67 & AV115 

Cover Kit

AV85 

Cover /kit

Seal Only

10mm

D2

AVTR1-D2

N/A

A36522-M2

A36524-M2

471959

11mm

DA

AVTR1-DA

N/A

A36522-MA

A36524-MA

471959

12mm

D3

AVTR1-D3

N/A

A36522-M3

A36524-M3

471960

14mm

DB

AVTR1-DB

N/A

A36522-MB

A36524-MB

471961

15mm

DC

AVTR1-DC

N/A

A36522-MC

A36524-MC

471961

16mm

DD

AVTR1-DD

N/A

A36522-MD

A36524-MD

471877

18mm

D4

AVTR1-D4

N/A

A36522-M4

A36524-M4

471962

19mm

DE

AVTR1-DE

N/A

A36522-ME

A36524-ME

471951

24mm

DF

AVTR1-DF

N/A

A36522-MF

A36524-MF

471964

28mm

DG

AVTR1-DG

N/A

A36522-MG

A36524-MG

471965

30mm

DH

AVTR1-DH

N/A

A36522-MH

A36524-MH

471966

32mm

DT

AVTR1-DT

N/A

A36522-MT

A36524-MT

471967

36mm

DJ

AVTR1-DJ

N/A

A36522-MJ

A36524-MJ

471968

38mm

DK

AVTR1-DK

N/A

A36522-MK

A36524-MK

471969

42mm

DL

AVTR1-DL

N/A

A36522-ML

A36524-ML

471969

45mm

DM

AVTR1-DM

N/A

A36522-MM

A36524-MM

471970

48mm

DN

AVTR1-DN

N/A

A36522-MN

A36524-MN

471971

52mm

DP

AVTR1-DP

N/A

A36522-MP

A36524-MP

471971

55mm

DR

AVTR1-DR

N/A

A36522-MR

A36524-MR

471972

60mm

DS

AVTR1-DS

N/A

A36522-MS

A36524-MS

471953

65mm

MU

N/A

AVTR1-MU

A36522-MU

A36524-MU

471954

70mm

MV

N/A

AVTR1-MV

A36522-MV

A36524-MV

471955

75mm

MW

N/A

AVTR1-MW

A36522-MW

A36524-MW

471956

80mm

MY

N/A

AVTR1-MY

A36737-MY

A36524-MY

471957

85mm

MZ

N/A

AVTR2-MZ

A36737-MZ

A36524-MZ

471958

Summary of Contents for AV56A

Page 1: ...ption code below 9xx Special Cable Length xx length in feet Equipment Needed for Installation Provided Optional Not Provided AV56A Stator Housing Socket Hd Cap Screw 3 8 16 x 1 25 4 AV56A Rotor Socket...

Page 2: ...021 0 58mm Tolerance 0 015 0 38mm F Rotor Axial Tolerance 0 050 1 27mm ENVIRONMENTAL Solid cast aluminum stator and rotor Fully potted electronics protected against oil and water spray Use W cable opt...

Page 3: ...B at the use end of the wires b Differential 2 Phase Wiring see wiring diagram Exchange either A with A in the phase A pair OR B with B in the phase B pair but NOT both 3 Apply Power 4 Verify encoder...

Page 4: ...ler and do not use a heat gun Instead insert two M6 screws 25mm length into the Jack Screw Holes shown in Fig 2 Alternately tighten the screws to push the rotor away from the motor and remove it LARGE...

Page 5: ...7 MIN A ADD L SHAFT LENGTH REQ D FOR V RING 0 19 0 02 4 6 0 5 0 24 0 03 6 1 0 8 0 28 0 04 7 1 1 0 0 35 0 05 8 9 1 3 2 75 3 00 70 0 79 4 0 38 9 7 MIN 0 35 0 05 8 9 1 3 Add 0 22 5 6 for cover depth 3 00...

Page 6: ...CK N A A36521 TK A36523 TK 471970 1 875 1 8745 AVTR1 CL N A A36521 TL A36523 TL 471970 2 000 1 9995 AVTR1 CM N A A36521 TM A36523 TM 471971 2 125 2 1245 AVTR1 CN N A A36521 TN A36523 TN 471972 2 250...

Page 7: ...4mm DF AVTR1 DF N A A36522 MF A36524 MF 471964 28mm DG AVTR1 DG N A A36522 MG A36524 MG 471965 30mm DH AVTR1 DH N A A36522 MH A36524 MH 471966 32mm DT AVTR1 DT N A A36522 MT A36524 MT 471967 36mm DJ A...

Page 8: ...ICATIONS FOR SINGLE ENDED SINGLE PHASE APPLICATIONS REF SIGNAL V A B COM V out ALM REF SIGNAL V SIG COM V out ALM OPTION G Q OPTION Y OPTION L W OPTION G Q OPTION Y OPTION P Z OPTION L W OPTION G Q OP...

Page 9: ...0 mA MAXIMUM WITHSTAND 50 V MAXIMUM REFERENCED TO COMMON Q5 MMFT6661 ENCODER FUNCTIONAL DIAGRAM B A A B LINE DRIVER NOTE 1 CR8 L W P Z Example 2 Alarm Output Using Separate 24 VDC Power Supply and Rel...

Page 10: ...114 4016 DIA OPTIONAL COVER FOR EXTENDED SHAFT MOTORS 1 97 50 0 2 74 69 9 OPTIONAL ISOLATED DUAL OUTPUT 1 2 14 NPT OPTION P G PLUG IN INDUSTRIAL CONNECTOR ADDITIONAL OPTIONS SHOWN 0 410 10 41 DIA 4 H...