Extreme Temperature Sensor Features & Specifications 

Environment Condition Monitored

 .................. Extreme-cold ambient temperatures 

Type Of Sensor

 ................................................... Analog 

Power Supply

 ...................................................... 18V power adapter 

     Included .......................................................... Yes 

Thermocouple

 

     Included .......................................................... Yes 
     Length ............................................................. 10' 

     

Operating Range ............................................. -328º F to 32º F (-200º C to 0º C) 

     Steps Between Temperature Readings ............ Approximately 2.37º F (1.32º C) 

Sensor Cable Type

 ............................................. Low-voltage, 2-wire speaker cable

 

     Included .......................................................... Yes 
     Length ............................................................. 25' 

 

     Maximum Extendible Length ......................... 900' 

Sensor ID Box Operating Range

....................... -40º F to 185º F (-40º to 85º C) 

Compatible Products

 ......................................... Room Alert 32E/W & 12E (built-in Analog Input Port);   

 ............................................................................. 

Digital Temperature & Analog Sensor 

AVT–140527.07 

Summary of Contents for RMA-ET1-SEN

Page 1: ...nsor Package Contents One 1 Extreme Temperature Sensor One 1 10 thermocouple coil w 2 probe One 1 18V power adapter One 1 25 speaker wire Two 2 mounting screws One 1 Installation Note You re reading it now Extreme Temperature Sensor And Power Ports Install Your Extreme Temperature Sensor Step 1 Locate the thermocouple and mount the sensor Your Extreme Temperature Sensor comes with a 10 thermocoupl...

Page 2: ...ree ends of the speaker wire Expose about of wire 2 Insert the silver wire into the RIGHT contact of the Analog Sensor Input port 3 Insert the copper wire into the LEFT contact of the Analog Sensor Input port Early versions of the Room Alert 12E have this polarity reversed LEFT negative and RIGHT positive If you observe your voltage value flipping back and forth from 0 to 5 it s likely that the sp...

Page 3: ...Cryo 15 or Freezer Rm Temp You may leave the High and Low for Analog at the default 0 which means no alarm is configured or enter values of up to 6 characters These values must be within the range you enter in Scale in the next step and cannot contain decimal points Your Room Alert monitor generates alerts based on those thresholds In Adjust you may leave the default 0 or enter a value between 12 ...

Page 4: ...adings will be measured in so enter F for Fahrenheit or C for Celsius 3 Click Accept Changes at the bottom of your screen to temporarily save your settings You may now navigate to another screen however if you close the web interface before the next step you will lose your changes 4 Click Save Settings in the navigation bar to the left of your screen Your Room Alert will automatically reboot and c...

Page 5: ...dapter Included Yes Thermocouple Included Yes Length 10 Operating Range 328º F to 32º F 200º C to 0º C Steps Between Temperature Readings Approximately 2 37º F 1 32º C Sensor Cable Type Low voltage 2 wire speaker cable Included Yes Length 25 Maximum Extendible Length 900 Sensor ID Box Operating Range 40º F to 185º F 40º to 85º C Compatible Products Room Alert 32E W 12E built in Analog Input Port D...

Reviews: