INSTALLATION 

1. Use the supplied three screws to attach and fix the bracket to wall.   
2. Remove the Joint Lock from the bracket by turning it counterclockwise. Then, connect the Joint Lock to the 

backside of the camera (turn clockwise). 

NOTE: 

There are two screw holes on the backside of the camera. Please choose the proper one which 

best suits your installation environment.   

3. Connect the camera with the Joint Lock connected to the bracket. After that, secure the Joint Lock to fix.   

 

 

 

Figure 1 

Figure 2 

Figure 3 

4. Connect the camera video output to DVR’s video input with a 75

 coaxial cable. Then, connect the camera to 

power with a DC 12V power supply. 

5. After installation, please follow the next section below to start selecting focal length and adjusting focus. For 

further camera angle change, the tilt angle of the camera is limited to 30 degrees and the right/left pan angle is 

limited to 15 degrees each.   

NOTE:

 

Please use the correct power adaptor, DC12V (regulated), to operate this unit. The power tolerance of this 

unit is DC12V ± 10%. Over maximum DC 12V power input will damage this unit.

 

 

NOTE:

 

To ensure the camera has sufficient protection against moisture, an extra waterproof measure, such as by 

using an insulating tape, must be used to cover the power and video connectors after connection.

 

 

FOCAL LENGTH SELECTION AND FOCUS ADJUSTMENT 

NOTE:

 

The appropriate temperature for focal length selection and focus adjustment is 0

˚

C

 ~ 40

˚

C

.

 

1. Rotate the front cover to remove it. 

Note: 

The camera front cover must be removed for focal length selection and focus adjustment: 

  Please finish focal length selection and focus adjustment ASAP and replace the front cover back as 

described in the following steps. 

  Please prevent doing this in the high moisture environment. If it’s inevitable, please finish it ASAP. 

 