PAGE 30
W i n d o w s P C S o f t w a r e E T I D e c o d e r
7.5.1
Submenu Com Port
If the message
PC not connected
1
appears, please check the selected COM
port under the submenu
Configuration
->
COM Port
and change the set-
tings. Factory settings are:
19200 Baud
and Parity
None
.
FIG. 13
COM PORT KONFIGURATION
7.5.2
Submenu System Configuration
7.5.2.1
Configuration of the Line interface
FIG. 14
CONFIGURATION OF THE LINE INTERFACE
The page
Line Interface
allows the configuration of the
2-Mbit/s
interface.
As reference clock you should normally select
Recovered Clock
. This setting
generates the clock from the incoming 2-Mbit signal.
Alternatively you can use the setting
External Clock
, if you have connected
an external clock to the clock input. The setting
Internal Clock
is only for test
purposes. In this case the clock is generated by the system.
1 If the connection is faulty try 9600 Baud and Parity Odd.