Chapter 4: Web Interface
35
NOTE:
On ESP-2 MI hubs, the physical interface and termination are changed in hardware. See
Changing the
Serial Port Interface on ESP-2 MI Hubs
on page 75 for more information.
To display or change the port interface:
1.
From the Main Menu, select
Port Interface
. The Serial Port Selection window will open.
2.
Select a port number or
all ports
, then click
Apply
.
•
On ESP-2 MI hubs, you may display interface information for port 1 or port 2 (the
all
ports
option is not available). If the RS-485 interface was configured in hardware, you
may change the transfer mode.
•
On ESP-16 MI hubs, ports 1-8 support multi-interface (ports 9-16 are dedicated RS-232),
so only 1-8 will be displayed. If
all ports
is selected, only ports 1-8 will be affected.
The Serial Attributes window will open.
•
If a single port was selected, the display contains the current port interface value.
•
If
all ports
was selected, the display contains the default port interface mode (RS-232),
which may differ from the current values for any port.
3.
To change the interface, select a value from the Port Interface listbox.
4.
If you select RS-422 or RS-485, you may also set a radio button in the RS422/RS485
Termination field to enable or disable 100 ohm termination. See
Termination
on page 7 for
more information.
5.
For ESP-2 MI hubs configured for RS-485 in hardware, the Transfer Mode (RS485) field
indicates the current transfer mode. (If the port is hardware-configured for another interface
type, this field indicates Not Applicable.) To change the transfer mode, select
RTS
or
ADDC
from the listbox. See
RS-485 transmitter and receiver transfer modes
on page 7 for
more information.
6.
If you changed the interface, click
Apply
. The change will take effect immediately.
Warnings and errors
A warning will be displayed (but the change will be allowed) if the RS-422 or RS-485 interface is
enabled and:
•
Hardware flow control is enabled in the port attributes.
•
Monitor DCD is enabled for the TCP server or TCP client connection methods, and those
methods are enabled.
•
Modem emulation is enabled.
If these changes were applied to all ports, the warning will indicate the affected ports.
Summary of Contents for ESP Serial Hub
Page 1: ...Installer User Guide ESP Serial Hub...
Page 2: ......
Page 14: ...4 ESP Serial Hub Installer User Guide...
Page 24: ...14 ESP Serial Hub Installer User Guide...
Page 52: ...42 ESP Serial Hub Installer User Guide...
Page 64: ...54 ESP Serial Hub Installer User Guide...
Page 95: ......
Page 96: ......