background image

 

2.6

 

Set operating mode 

 

permanent:

 When switched on using the mains switch (13), the unit is permanently ready to 

operate until it is switched off with the mains switch. 

automatic:

  The  amplifier  switches  on  automatically  as  soon  as  a  connected  pre-amplifier 

delivers an audio signal to one of the analog inputs (7, 8).  Standby mode is activated as soon 
as the pre-amplifier has not delivered a signal for more than 10 minutes. 

trigger:

 Switching to operating mode and to standby is controlled via the trigger input (10). 

For details, see section 1.6. 

remote: 

If you happen to use an AVM model of the PA or SD series as a pre-amplifier, your 

MA / SA 6.2 can be automatically switched on and off via inaudible digital signals sent over a 
connected  audio  cable  –  without  the  need  for  an  additional  trigger  cable.  In  addition,  the 
display brightness can also be remotely controlled – according to the selected setting on the 
pre-amplifier (see section 2.4).

 

 

2.7

 

Define load impedance 

 
To  obtain  correct  values  in  the  power  display  (see  2.5),  it  is  necessary  to  select  the given 
impedance according to your speakers (4 or 8 Ohms). This setting is only for calibrating the 
power display and has no influence on the performance of the amplifier itself. 
 
 
 
 

3

 

Reset (Factory settings) 

 
The 

Reset

 menu cancels certain or all settings and makes the unit return to default settings. 

 
To enter the 

Reset

 menu, please switch off your device on the rear of the unit at the mains 

switch (13). Keep the middle key under the display pressed (3) while you switch on the unit 
again (13). As soon as the display shows the reset menu

 

you can

 

release the multifunctional 

button under the display (3). Now press 

ALL

 to reset the unit completely. 

CANCEL

 will bring 

the unit back to normal operating mode without resetting any item. 
 
After  resetting  your  MA  /  SA  6.2,  the  unit  needs  to  be  restarted  at  the  mains  switch  (13). 
Switch off the unit, wait for a couple of seconds and turn it on again to complete the reset 
procedure.

 

4

 

Appendix 

4.1

 

Cleaning 

 

Use a soft cloth and normal glass cleansing fluid. 

 

CAUTION

  

Make sure no fluid gets into the unit. Do not use scouring cleaners. They may damage the 
surface. 
 
 

 

Summary of Contents for OVATION MA 6.2

Page 1: ...Operating Instructions OVATION MA 6 2 OVATION SA 6 2 ...

Page 2: ...irmware update at any time Hence the present operating instructions will require continued updates going forward You can always download the most current version from our website at www avm audio Sincerely yours The AVM Team Declaration of conformity for EC only We herewith confirm that the unit to which this manual belongs fulfills the EC rules necessary to obtain the sign the necessary measureme...

Page 3: ...s 4 1 7 Connecting loudspeakers 4 1 8 Packing advice 4 2 Basic operation and advanced settings menu 5 2 1 Operating mode Standby mode 5 2 2 Display button 5 2 3 Advanced settings menu 5 2 4 Set display brightness 5 2 5 Set display mode 5 2 6 Set operating mode 6 2 7 Define load impedance 6 3 Reset Factory settings 6 4 Appendix 6 4 1 Cleaning 6 4 2 Troubleshooting 7 4 3 Conditions of warranty EC on...

Page 4: ... numeric of the MA SA 6 2 It is also useful to make settings via the intuitive menu system Configuring the display power bar value display peak power only and display off setting the display brightness setting the operating mode permanent automatic trigger remote and setting the actual speaker impedance If you happen to use an AVM model of the PA or SD series as a pre amplifier your MA SA 6 2 can ...

Page 5: ...7 Analog input balanced XLR 8 Analog input unbalanced Cinch RCA 9 Configuration port 10 Trigger input TRIGGER IN 11 Phase LED 12 Mains outlet 13 Mains switch 1 2 3 Pin assignment XLR input und Trigger input XLR Eingang 7 3 5 mm trigger input 10 1 3 2 ...

Page 6: ...voltage is according to the value printed on the rear panel of the amplifier near mains connector Set the mains switch 13 to on push once CAUTION Keep the unit switched off until all audio connections are made Also keep your loudspeakers disconnected when switching the unit on for the first time Switch on the unit by pressing the power button 1 The unit performs a self test while the AVM logo appe...

Page 7: ...lips to the left speaker 6 We recommend to only use loudspeaker cables of good quality and with sufficient diameter to connect your loudspeaker to the output clips Take care of the correct polarity when connecting The red marked output clips must be connected to the red loudspeaker clip or marked with a plus sign Right and left channels must be the same polarity The SA 6 2 is equipped with two swi...

Page 8: ... menu point is indicated in the upper area of the display in capital letters the respective option is indicated below in lowercase characters To skip through the available menu points use the menu buttons named ITEM To change the setting or option of a selected menu point use the menu buttons named VALUE To store and exit the menu again just press the menu button EXIT NOTE If no menu button is pre...

Page 9: ...btain correct values in the power display see 2 5 it is necessary to select the given impedance according to your speakers 4 or 8 Ohms This setting is only for calibrating the power display and has no influence on the performance of the amplifier itself 3 Reset Factory settings The Reset menu cancels certain or all settings and makes the unit return to default settings To enter the Reset menu plea...

Page 10: ...ch the unit to permanent mode or to make use of a trigger cable see section 1 6 b If the unit is operated in trigger mode please check the trigger cables between the pre amplifier and the amplifier and ensure there are no breaks or short circuits in the cable c The unit is operated in remote mode without using a suitable pre amplifier such as an AVM SD or PA model Choose a different operating mode...

Page 11: ...defect is to be included with the returned unit In cases of doubt we reserve the right to request a copy of the bill of sale We also reserve the right to levy a handling charge for items returned without good or valid reason or if the unit proves to be not defective NOTE If you are returning the unit from a country other than Germany you should ensure that correct export documents are obtained We ...

Page 12: ... Amplifier Input impedance Cinch XLR 6 8 kOhms Signal to noise ratio SNR 101 dB A Frequeny response 5 Hz 50 kHz THD 25 W 4 Ohms 0 1 Damping factor 200 Power 2 x 335 Watts 4 Ω 2 x 225 Watts 8 Ω 5 4 Other Supply voltage 115 230V 50 60Hz Power consumption max Standby Dimensions W x H x D 430 x 130 x 390 mm Weight ...