2.1

 

Operating mode / Standby mode 

 
Using  the  power  button  (1)  you  can  switch  between  the  operating  mode  and  the  standby 
mode. When switched on, the display (4) lights up and the control LED (2) is switched off. In 
standby mode, the display is switched off and the control LED is on to indicate the unit is still 
connected to the mains. 
 

CAUTION: 

When switched to standby, the unit is still connected to the mains. In case of a 

thunderstorm or if you leave the house for a longer time, we recommend you switch off the 
amplifier by using the mains switch (13) or pull the mains plug (12).

 

 
 

2.2

 

Display button 

 
If the display disturbs you while listening to music, you can switch it off by pressing the display 
button (5). 
 

2.3

 

Advanced settings menu 

 
The MA / SA 6.2 offers a wealth of custom-specific settings in its advanced settings menu 
which may be accessed during operating or standby mode. To enter the menu, just tap on 
the 

MENU

 button (3). The currently selected menu point is indicated in the upper area of the 

display in capital letters – the respective option is indicated below in lowercase characters. 
To  skip  through  the  available  menu  points,  use  the  menu  buttons

 

named

  <  ITEM  >

.  To 

change the setting or option of a selected menu point, use the menu buttons named 

< VALUE 

>

. To store and exit the menu again, just press the menu button 

EXIT. 

 

 

NOTE: 

If no menu button is pressed for ten seconds while the advanced settings menu is 

active, the amplifier switches back to normal operating mode. Settings made previously are 
still stored.  
 

2.4

 

Set display brightness 

 
Selects the display brightness from 100%, 75%, 50%, to 25%.  
 

NOTE

: The display brightness can also be remotely controlled, if an AVM model of the PA or 

SD series is used as a pre-amplifier and 

remote 

is set as operating mode (see section 2.6) 

 

2.5

 

Set display mode 

 

bargraph & value:

 While operating, a bar informs about the actual output level. The peak 

output power is displayed numerically. 

value:

 Only the peak output power is indicated numerically. 

 

CLIP

  indicates  the  demanded  output  power  exceeded  the  maximum.  In  this  case,  we 

recommend to reduce the volume in order to not damage the tweeters of your tweeters. 
 

Summary of Contents for OVATION MA 6.2

Page 1: ...Operating Instructions OVATION MA 6 2 OVATION SA 6 2 ...

Page 2: ...irmware update at any time Hence the present operating instructions will require continued updates going forward You can always download the most current version from our website at www avm audio Sincerely yours The AVM Team Declaration of conformity for EC only We herewith confirm that the unit to which this manual belongs fulfills the EC rules necessary to obtain the sign the necessary measureme...

Page 3: ...s 4 1 7 Connecting loudspeakers 4 1 8 Packing advice 4 2 Basic operation and advanced settings menu 5 2 1 Operating mode Standby mode 5 2 2 Display button 5 2 3 Advanced settings menu 5 2 4 Set display brightness 5 2 5 Set display mode 5 2 6 Set operating mode 6 2 7 Define load impedance 6 3 Reset Factory settings 6 4 Appendix 6 4 1 Cleaning 6 4 2 Troubleshooting 7 4 3 Conditions of warranty EC on...

Page 4: ... numeric of the MA SA 6 2 It is also useful to make settings via the intuitive menu system Configuring the display power bar value display peak power only and display off setting the display brightness setting the operating mode permanent automatic trigger remote and setting the actual speaker impedance If you happen to use an AVM model of the PA or SD series as a pre amplifier your MA SA 6 2 can ...

Page 5: ...7 Analog input balanced XLR 8 Analog input unbalanced Cinch RCA 9 Configuration port 10 Trigger input TRIGGER IN 11 Phase LED 12 Mains outlet 13 Mains switch 1 2 3 Pin assignment XLR input und Trigger input XLR Eingang 7 3 5 mm trigger input 10 1 3 2 ...

Page 6: ...voltage is according to the value printed on the rear panel of the amplifier near mains connector Set the mains switch 13 to on push once CAUTION Keep the unit switched off until all audio connections are made Also keep your loudspeakers disconnected when switching the unit on for the first time Switch on the unit by pressing the power button 1 The unit performs a self test while the AVM logo appe...

Page 7: ...lips to the left speaker 6 We recommend to only use loudspeaker cables of good quality and with sufficient diameter to connect your loudspeaker to the output clips Take care of the correct polarity when connecting The red marked output clips must be connected to the red loudspeaker clip or marked with a plus sign Right and left channels must be the same polarity The SA 6 2 is equipped with two swi...

Page 8: ... menu point is indicated in the upper area of the display in capital letters the respective option is indicated below in lowercase characters To skip through the available menu points use the menu buttons named ITEM To change the setting or option of a selected menu point use the menu buttons named VALUE To store and exit the menu again just press the menu button EXIT NOTE If no menu button is pre...

Page 9: ...btain correct values in the power display see 2 5 it is necessary to select the given impedance according to your speakers 4 or 8 Ohms This setting is only for calibrating the power display and has no influence on the performance of the amplifier itself 3 Reset Factory settings The Reset menu cancels certain or all settings and makes the unit return to default settings To enter the Reset menu plea...

Page 10: ...ch the unit to permanent mode or to make use of a trigger cable see section 1 6 b If the unit is operated in trigger mode please check the trigger cables between the pre amplifier and the amplifier and ensure there are no breaks or short circuits in the cable c The unit is operated in remote mode without using a suitable pre amplifier such as an AVM SD or PA model Choose a different operating mode...

Page 11: ...defect is to be included with the returned unit In cases of doubt we reserve the right to request a copy of the bill of sale We also reserve the right to levy a handling charge for items returned without good or valid reason or if the unit proves to be not defective NOTE If you are returning the unit from a country other than Germany you should ensure that correct export documents are obtained We ...

Page 12: ... Amplifier Input impedance Cinch XLR 6 8 kOhms Signal to noise ratio SNR 101 dB A Frequeny response 5 Hz 50 kHz THD 25 W 4 Ohms 0 1 Damping factor 200 Power 2 x 335 Watts 4 Ω 2 x 225 Watts 8 Ω 5 4 Other Supply voltage 115 230V 50 60Hz Power consumption max Standby Dimensions W x H x D 430 x 130 x 390 mm Weight ...