Avlite AV23 Installation & Service Manual Download Page 14

Latest products and information available at www.avlite.com

14

AV23 Solar Obstruction Light

Maintenance and Servicing

Designed to be maintenance free, the AV23 requires minimal attention, though the following 

maintenance and servicing information is provided to help ensure the life of your Avlite product. 
1.  Cleaning Solar Panels - occasional cleaning of the solar panels may be required. Using a cloth and 

warm soapy water, wipe off any foreign matter before rinsing the panels with fresh water.  

2.  Battery Check - inspection of batteries should be performed every three years (minimum) to ensure 

that the charger, battery and ancillary electronics are functioning correctly. Using a voltage meter, 

check that the battery voltage is at least 3.6 volts under 100MA load, and ensure all terminals are 

clear of foreign matter. 

Replacing the battery- Don’t throw the unit out!!  

The AV23 light battery compartment provides the user with the ability to change the battery after years of 

operation.
1.  Remove the 2 x M8 x 50 SHCS.
2.  Remove battery from AV23 case and disconnect the battery leads. 
3.  Discard old battery in a safe manner. 

4.  Reattach positive and negative leads to new battery and then place back into case. 
5.  Refit the light head. Tighten SHCS evenly and securely.
6.  To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on.

Care must be taken to observe the polarity of the battery before the leads are re-connected, and 

ensure the replacement battery is correctly fitted. Always discard old batteries in a safe manner. 

Long Term Storage Instructions

If the AV23 is to be placed in storage for an extended period, being more than 5 months, please follow 

the below steps.
1.  The 12 volt SLA Battery must be stored in a fully charged condition.
2.  Remove the light head.
3.  Disconnect the battery leads.
All batteries will discharge over time and the rate of discharge is dependent on temperature. If the light is 

being stored in temperatures greater than 40°C the battery will discharge faster.
Please check battery every 3-6 months and recharge if necessary.

Recharging the Battery

1.  Remove the light head and assembly. 
2.  Connect the battery leads.
3.  Reconnect the battery and place unit in the sun for 2-4 days

Or

Reconnect battery and place in front of a halogen lamp for 2-3 days. (Do not place the halogen light too 

close to the solar panel or the panel may be overheated)

Check the battery voltage regularly to make sure the unit is charging correctly.

Summary of Contents for AV23

Page 1: ...Version 2 2 AV23 Solar Obstruction Light Installation Service Manual...

Page 2: ...rge 10watt adjustable tilt solar module to maximise solar radiation collection for charging the battery Interchangeable LED flasher unit and replaceable lens assembly User replaceable battery in large...

Page 3: ...l Update July 2010 K Paton 2 2 Updated light head November 2010 M Henry Introduction Page 4 Operating Principle Page 4 Technology Page 4 AV23 Model Page 5 Installation Page 7 Selecting an Intensity Po...

Page 4: ...e will turn on Technology Avlite Systems is a world class solar lighting systems manufacturer with a proven reputation for rapid innovative and agile technology solutions designed specifically for def...

Page 5: ...n Light AV23 Model The AV23 is a low intensity solar powered obstruction light designed to offer users years of maintenance free operation The unit is completely self contained and incorporates a larg...

Page 6: ...l Circuit Protection Integrated Nominal Voltage v 12 Temperature Range 40 to 80 C Solar Characteristics Solar Module Type Multicrystalline Output watts 10 1 x 10watt Solar Module Efficiency 14 Chargin...

Page 7: ...rn is normally set to maximum range see Selecting an Intensity Setting section of this manual 4 Set rotary switches to the required flash code see Selecting a Flash Code section of this manual also lo...

Page 8: ...ycle All lights have 2 rotary switches marked A and B on the flasher unit Turning the small arrows to the appropriate number or letter will set the code see Flash Codes section of this manual The unit...

Page 9: ...le VQ 6 LFL 10 S means 6 very quick flashes followed by a long flash during a 10 second interval The amount of power your light draws through the night depends on the duty cycle i e the amount of time...

Page 10: ...0 1 0 3 1 FL 4 3 S 1 3 3 0 8 5 FL 5 S 0 2 4 8 4 1 FL 5 S 0 3 4 7 5 1 FL 5 S 0 5 4 5 9 5 FL 5 S 0 9 4 1 6 1 FL 5 S 1 0 4 0 SWITCH FLASH CODE ON OFF A B 7 1 FL 5 S 1 5 3 5 4 2 ISO 5 S 2 5 2 5 8 2 LFL 5...

Page 11: ...2 0 5 0 8 A FL 2 8 S 0 4 1 0 0 4 6 2 4 7 FL 2 8 S 0 5 1 0 0 5 6 0 8 8 FL 2 8 S 0 8 1 2 2 4 3 6 5 7 FL 2 8 S 1 0 1 0 1 0 5 0 4 C OC 2 8 S 3 0 2 0 1 0 2 0 5 C OC 2 8 S 5 0 1 0 1 0 1 0 F B VQ 2 8 S 0 2 1...

Page 12: ...7 1 9 FL 2 1 15 S 0 7 0 7 0 7 0 7 2 1 10 1 6 8 FL 2 1 15 S 1 0 2 0 1 0 5 0 1 0 5 0 1 C VQ 3 15 S 0 1 0 5 0 1 0 5 0 1 13 7 4 B FL 3 20 S 0 5 3 0 0 5 3 0 0 5 12 5 3 B FL 3 20 S 0 5 1 5 0 5 1 5 0 5 15 5...

Page 13: ...0 7 0 7 0 7 2 1 10 1 7 D MO B 15 S 1 5 0 5 0 5 0 5 0 5 0 5 0 5 10 5 SWITCH FLASH CODE ON OFF ON OFF ON OFF ON OFF ON OFF A B D D Q 5 7 S 0 3 0 7 0 3 0 7 0 3 0 7 0 3 0 7 0 3 2 7 E D Q 5 10 S 0 3 0 7 0...

Page 14: ...d negative leads to new battery and then place back into case 5 Refit the light head Tighten SHCS evenly and securely 6 To test place dark cover towel or jacket on top of light to activate sensor ligh...

Page 15: ...ure contacts are clear Light will not operate for the entire night Expose light to direct sunlight and monitor operation for several days Avlite products typically require 3 0 hours of direct sunlight...

Page 16: ...Latest products and information available at www avlite com 16 AV23 Solar Obstruction Light Notes...

Page 17: ...Latest products and information available at www avlite com 17 AV23 Solar Obstruction Light Notes...

Page 18: ...se subject to the conditions hereinafter set forth for a period of three 3 years from the date of purchase by the original purchaser 4 Avlite Systems will repair or replace at Avlite s sole discretion...

Page 19: ...lar purpose or with respect to any other matter relating to any products Limitation of Liability To the extent permitted by section 68A of the Trade Practices Act 1974 Cth the liability of Avlite Syst...

Page 20: ...d perimeter lighting Obstruction Lighting For a complete list of product compliances including ICAO FAA please contact Avlite today Radio Controlled PALC Systems FCC Compliant Airfield Markers Accesso...

Reviews: