SPECIFICATIONS•*

AV-SAL-01

Light Characteristics

Light Source

8 ultra-high intensity white (warm daylight) LEDs

LED Life Expectancy (hours)

>50,000

Photometry

Total Luminous Flux (lm)

1360

Luminous Efficiacy (lm/W)

69.7

Electrical Characteristics

Voltage (V)

12

Current (A)

1.7

Power (W)

20

Power Factor

1.0

Circuit Protection

Integrated

Temperature Range

-40 to 55°C

Spectral Characteristics

CIE 1931 2 deg observer (x,y)

 (1)

(0.312, 0.336)

CIE 1976 2 deg observer (u’,v’)

 (1)

(0.195, 0.472)

Correlated Color Temperature

(1)

6500 K

Color Rendering Index

(1)

71

Color Spatial Uniformity

(2)

0.0207

Solar Characteristics

Solar Module Type

Multicrystalline

Output (watts)

140W

Solar Module Efficiency (%)

14

Charging Regulation

Integrated charge regulator

Power Supply

Battery Type

SLA (Sealed Lead Acid)

Battery Capacity (Ah)

110Ah (2 x 55Ah batteries)

Nominal Voltage (V)

12

Operation without sunlight  

(autonomy nights)

5 night (typical)

Physical Characteristics

Body Material (light head)

Extruded aluminium chassis with LEXAN® polycarbonate glass filled end 

caps - UV-stabilised

Lens Material (light head)

LEXAN® Polycarbonate – UV stabilized

Mounting (light head)

Adjustable along 78mm parallel channels

Height (light head) (mm/inches)

85 / 3

3

/

8

Width (light head) (mm/inches)

108 / 4

1

/

4

Length (light head) (mm/inches)

300 / 11

7

/

8

Mass (light head) (kg/lbs)

1.5 / 3.3

Body Material (post)

Mild steel (hot-dipped galvanised)

Mounting (post)

4 x 22mm holes

Height (complete assembly)  

(mm/inches)

7160 / 281

7

/

8

Mass (complete assembly) 

(kg/lbs)

250 / 551

Product Life Expectancy

Up to 12 years

Certifications

CE

EN61000-6-3:1997. EN61000-6-1:1997

Quality Assurance

ISO9001:2008

Intellectual Property

Trademarks

AVLITE® is a registered trademark of Avlite Systems

Warranty *

3 year warranty

Options Available

• Radio controlled

• Avlite Pilot Activated Lighting Control

• Dual arm assembly

Summary of Contents for AV-SAL-01

Page 1: ...Version 2 1 AV SAL 01 Solar Area Light Installation Service Manual...

Page 2: ...module Adjustable light arm Galvanised post Anti tamper fittings UV stabilised LEXAN polycarbonate lens containing 8 ultra high intensity LEDs for optimal area illumination 120 degrees Battery sectio...

Page 3: ...ugust 2010 M Henry 2 0 Product Code change October 2012 J Dore 2 1 Spec table update January 2013 J Dore Introduction Page 4 Operating Principle Page 4 Technology Page 4 AV SAL 01 Model Page 5 Install...

Page 4: ...will turn on Technology Avlite Systems is a world class solar lighting systems manufacturer with a proven reputation for rapid innovative and agile technology solutions designed specifically for defe...

Page 5: ...such as shelters car parks and maintenance areas where connection to power grids is unfeasible The assembly uses the latest technologies in Light Emitting Diodes LEDs as a light source and provides ex...

Page 6: ...Latest products and information available at www avlite com 6 AV SAL 01 Solar Area Light Fig 2 AL 01 Light Head...

Page 7: ...rystalline Output watts 140W Solar Module Efficiency 14 Charging Regulation Integrated charge regulator Power Supply Battery Type SLA Sealed Lead Acid Battery Capacity Ah 110Ah 2 x 55Ah batteries Nomi...

Page 8: ...ns and wind loading in general refer to AS1170 2 BASIC WIND SPEEDS IN DIFFERENT REGIONS Regions serviceability VS m s permissible limit Vp m s ultimate Vu m s Normal A 38 41 50 Intermediate B 38 49 60...

Page 9: ...n in Figure 3 Footing design is based on typical soil having a bearing strength of 120kpa or greater If the soil is poor variable or rock then seek additional engineering advice 6 a Use a simple templ...

Page 10: ...k the contents of the package Verify that all components and hardware have been received Please contact your Avlite office if any components are missing or damaged Item Description Quantity 1 Area Lig...

Page 11: ...le Feed the solar cable down through the centre of the area light pole and into the battery housing This will need to be done during the installation of the solar array Tighten the M10 locking screws...

Page 12: ...Latest products and information available at www avlite com 12 AV SAL 01 Solar Area Light Fig 6 Solar Area Light Electrical Wiring Diagram...

Page 13: ...ition Preferred Installation Location For best light performance ensure solar modules are not covered and are in clear view of the sky with no shadows Light Operation 1 The AV SAL 01 will be preset at...

Page 14: ...to the battery positive terminals on the batteries 3 Connect the Solar Negative wire from the solar panel to the regulator 4 Connect the Solar Positive wire from the solar panel to the regulator 5 Co...

Page 15: ...be required Using a cloth and warm soapy water wipe off any foreign matter before rinsing the panels with fresh water 2 Battery Check inspection of batteries should be performed every three years min...

Page 16: ...s above 12 5volts Light will not operate for the entire night Expose light to direct sunlight and monitor operation for several days Avlite products typically require 1 5 hours of direct sunlight per...

Page 17: ...Latest products and information available at www avlite com 17 AV SAL 01 Solar Area Light Notes...

Page 18: ...e subject to the conditions hereinafter set forth for a period of three 3 years from the date of purchase by the original purchaser 4 Avlite Systems will repair or replace at Avlite s sole discretion...

Page 19: ...ar purpose or with respect to any other matter relating to any products Limitation of Liability To the extent permitted by section 68A of the Trade Practices Act 1974 Cth the liability of Avlite Syste...

Page 20: ...perimeter lighting Obstruction Lighting For a complete list of product compliances including ICAO FAA please contact Avlite today Radio Controlled PALC Systems FCC Compliant Airfield Markers Accessor...

Reviews: