9.0 Troubleshooting
Problem
Possible Cause
Solution
Light will not activate
No power to light
• Check battery terminals are properly connected.
•
Check battery voltage is above the flat battery
threshold.
Ambient lighting
conditions
• Ensure internal toggle switch is set to the ‘ON’
position.
• Ensure light is in darkness.
•
Wait at least 60 seconds for the program to
initialise in darkness.
Light will not operate
for the entire night.
Insufficient Charging
• Expose light to direct sunlight and monitor
operation for several days. Avlite products
typically require 2.5-3.0 minimum hours of direct
sunlight per day to retain full autonomy. From
a discharged state, the light may require several
days of operational conditions to ‘cycle’ up to
full autonomy.
• Ensure solar module is clean and not covered by
shading during the day.
Lights are constantly
on during the day.
Incorrect Operation
Mode
• Check the Operational Mode setting in AvlitePro
is not set to ‘Always ON’