AVL DiTEST ADS 340
List of possible faults / troubleshooting
User Manual
10-3
Device check incomplete.
Replace refrigerant bottle.
The device scan can not be completed due to insufficient amount
of refrigerant.
The refrigerant cylinder must be replaced.
Measurement data invalid,
calibration failed.
If during calibration incorrect measured data calibration is
detected aborted with this error message.
Not enough refrigerant for
calibration, refrigerant
bottle must be replaced.
The calibration can not be performed because the amount of
refrigerant required for the calibration is not available. The
refrigerant bottle must be replaced.
Error message
Possible cause(s), Solution
System error
An error indicates that the device because of a problem
cannot be used for the time being or permanently.
Charging indicator: red flashing quickly.
Check pressure sensors.
It was detected an invalid signal on one of the pressure sensors.
All pressure sensors must be checked
.
Check temperature
sensors.
It was detected an invalid signal on one of the temperature
sensors. All temperature sensors must be checked
.
Check weight sensors.
One of the scales provides an invalid signal.
All balances must be checked
.
CO
2
concentration is above
safety limit. Air the room.
CO
2
concentration is above the recommended limit.
Make sure there is good ventilation and you leave the room until
the CO
2
concentration has fallen back to normal levels and the red
flashing light goes out
.
CO
2
sensor is not available. CO
2
sensor is not connected.
The device cannot be used for safety reasons.
The CO
2
sensor must be checked.
Pressure of refrigerant
bottle too high.
The pressure of the refrigerant cylinder is outside the safety limits.
The device cannot be used until the pressure is back within the
safety limits
.
System pressure too high.
The pressure at the couplings exceed the safety limits.
The device cannot be used until the pressure is at the couplings
again within the safety limits
.
Error/Error messages, electrical:
Error/Error message
Possible cause(s)
Solution
Cannot be switched on
No power supply
Check power supply.
Check fuses.
Error/Error messages, mechanical:
Error/Error message
Possible cause(s)
Solution
Self-check is not starting
No gas supply
Connect or open supply
Disconnect vehicle
Close gas bottle and drain manually
Not enough oil available
Oil tank empty
Fill oil bottle
Check connection
Vehicle not
connected or empty
Connect quick coupling to vehicle
Oil filling
– fill level not
reached
Oil tank empty
Fill oil bottle
Circuit under pressure
Perform draining
Summary of Contents for ADS 340
Page 4: ...Warning and safety notices AVL DiTEST ADS 340 II User Manual ...
Page 15: ...AVL DiTEST ADS 340 GENERAL SAFETY INSTRUCTIONS User Manual XIII ...
Page 18: ......
Page 30: ...General AVL DiTEST ADS 340 1 12 User Manual ...
Page 40: ...Commissioning AVL DiTEST ADS 340 2 10 User Manual ...
Page 87: ...AVL DiTEST ADS 340 Maintenance User Manual 6 37 ...
Page 88: ......
Page 90: ...Service AVL DiTEST ADS 340 7 2 User Manual ...
Page 92: ...Overview AVL DiTEST ADS 340 8 2 User Manual ...
Page 98: ...List of possible faults troubleshooting AVL DiTEST ADS 340 10 4 User Manual ...
Page 99: ...AVL DiTEST ADS 340 List of possible faults troubleshooting User Manual 10 5 ...
Page 100: ......
Page 102: ...Warranty AVL DiTEST ADS 340 11 2 User Manual ...
Page 108: ...List of Abbreviations AVL DiTEST ADS 340 14 2 User Manual ...
Page 111: ......
Page 112: ......