AVK 3001/004 Installation, Operation And Maintenance Manual Download Page 5

 

Page 5 of 8 

Based on AVK-Tech form no. 04.186, rev 3, 15-Nov-2018 

Copyright © AVK Holding A/S, original version, rev. 4, 05-MAY-

2021

 

7.  Disposal and recycling 

This symbol on the product or packaging indicates that this product should not be 
disposed with household waste. Instead, it is responsible to dispose of waste by 
taking it to a designated collection point for recycling electrical and electronic 
devices. Separate collection and recycling of waste at disposal will help conserve 
natural resources and ensure environmentally and human-friendly recycling.  

 
For more information about the recycling station closest to your home, contact the nearest town 
hall waste disposal service or the company where the product was purchased. 
 

 
Ensure that the rules for the collection of waste and the rules for the correct disposal 
and recycling are always respected. 

8.  Notes 

All rights to this manual are exclusive to the Manufacturer. Copying and translating this manual 
is prohibited without a written permission from the owner. 
 
The Manufacturer reserves the right to modify the technical specifications or functions of its 
products, to cease production of one of its products or to discontinue technical support for one 
of its products without notice in writing. The Manufacturer urges its customers to ensure that the 
information in their possession is valid and updated.

 

9.  Device features 

The AVK Smart Water VIDI Level Sensor transmitter has the following specifications:  
 

Transmitter: 

 

Dimensions 

H. 163 mm x L. 58 mm x W. 43 mm 

Weight 

0.15 kg 

Security 

IP68 

Modulation 

LoRa 

Battery capacity 

10 Years 

Wire length 

1 m or 3 m 

Operating temperature 

-40 °C up to 65 °C 

Level sensor incl. Mounting bracket: 

 

Dimensions 

H. 145 mm, L. 80 mm, W. 50 mm 

Sensor range 

0 m 

– 5 m 

Sensor detection 

Detects range to first detectable surface 

Security 

IP67 

Summary of Contents for 3001/004

Page 1: ...v 3 15 Nov 2018 Copyright AVK Holding A S original version rev 4 05 MAY 2021 Installation Operation and Maintenance Manual Version 5 00 VIDI LEVEL SENSOR 3001 004 For measuring distance to the nearest surface and transmitting data to the VIDI Cloud ...

Page 2: ...001 004 detailed view Mounting example 3 2 Manufacturer 4 3 Product information 4 4 General warnings and security measures 4 5 Testing 4 6 Warranty 4 7 Disposal and recycling 5 8 Notes 5 9 Device features 5 10 Operation and installation 6 10 1 Step by step installation guide 6 10 2 Operation description 6 10 3 Activation deactivation 6 10 1 App features 7 10 2 Battery replacement 8 ...

Page 3: ...opyright AVK Holding A S original version rev 4 05 MAY 2021 1 AVK series and type 3001 004 detailed view Mounting example NOTE AVK has valves available with bosses for mounting additional equipment Please contact local AVK sales representatives for more information ...

Page 4: ...structions Installation must be carried out by personnel who are properly trained to operate on plants where they will be able to install the device Therefore it is absolutely forbidden to install the device if you are unexperienced The device must be installed in sufficiently airy places to prevent any internal overheating Do not place the device in the vicinity of living flames such as candles t...

Page 5: ...t disposal and recycling are always respected 8 Notes All rights to this manual are exclusive to the Manufacturer Copying and translating this manual is prohibited without a written permission from the owner The Manufacturer reserves the right to modify the technical specifications or functions of its products to cease production of one of its products or to discontinue technical support for one o...

Page 6: ...ansmitter sends a data package every 30 minutes containing a message with the measured values with five minutes resolution In case an alarm is detected tamper or battery alarm an additional data package is sent immediately 10 3 Activation deactivation Transmitters are shipped with radio mode off Once the installation of the transmitter is complete the transmitter must be activated This is done by ...

Page 7: ...ctivated which is described in this section Read distance This button allows the user to read a local distance measurement immediately once pressed The returned value is from 0 100 which corresponds to the total range of the level sensor example The measured value on the phone s display shows 50 0 and using a level sensor 0 5 meter the real distance value is 2 5 meters During field testing and dev...

Page 8: ...mal conditions and use The battery replacement can be done by opening the container and replacing the battery enclosed Replace it with a battery of the same characteristics the same connector and the same polarity Battery type Non rechargeable lithium ions Tension 3 6 V Capacity 9000 mAh Size C Once the battery is replaced in the case of LoRaWAN transmitters the message counters are reset to zero ...

Reviews: