AVK 3001/004 Installation, Operation And Maintenance Manual Download Page 4

 

Page 4 of 8 

 

Copyright © AVK Holding A/S, original version, rev. 4, 05-MAY-2021 

Based on AVK-Tech form no. 04.186, rev 3, 15-Nov-2018

 

2.  Manufacturer 

ASW-ATI Srl 
Via Volontari della Liberta', 54/56, 50053 Empoli FI 

– ITALY (the ‘Manufacturer’) 

 
The Manufacturer is a subsidiary of AVK Holding A/S (the ‘AVK Group’). 
AVK Smart Water is a brand name of the AVK Group. 

3.  Product information 

Thank you for purchasing this product. Please read the instructions carefully for information 
about use and safety standards. 
 
AVK logo and model identification data are displayed on the body of the device (via adhesive 
tag). 

4.  General warnings and security measures 

  Please read this manual carefully, before using the device. All use and installation 

instructions are described in this publication that must be stored and found in the 
workplace.  

  Failure to comply with safety standards can have serious consequences for p

eople’s 

safety and the operation of the device. The Manufacturer will not take any responsibility 
for damages resulting from failure to comply with these instructions. 

  Installation must be carried out by personnel who are properly trained to operate on 

plants where they will be able to install the device. Therefore, it is absolutely forbidden to 
install the device if you are unexperienced. 

  The device must be installed in sufficiently airy places to prevent any internal 

overheating. 

  Do not place the device in the vicinity of living flames such as candles, torches, etc. 

  The device should not be exposed to aggressive chemicals that can damage the plastic. 

5.  Testing 

Before being sent to the customer, all products are subject to appropriate final testing according 
to an internal control plan. 

6.  Warranty 

The Manufacturer provides a product guarantee to the distributor or customer for a period of 12 
consecutive months. The start date of the warranty coverage period will be the delivery date. 
Any faults or defects should be reported within eight days of their discovery. 
 
All parts manufactured/supplied by the Manufacturer are covered by the warranty. However, 
damage caused by normal wear and tear are excluded from the terms of this warranty.  
 
In addition, damages determined to be due to improper installation or misuse of the device 
according to the Manufacturer are excluded from the warranty.  

Summary of Contents for 3001/004

Page 1: ...v 3 15 Nov 2018 Copyright AVK Holding A S original version rev 4 05 MAY 2021 Installation Operation and Maintenance Manual Version 5 00 VIDI LEVEL SENSOR 3001 004 For measuring distance to the nearest surface and transmitting data to the VIDI Cloud ...

Page 2: ...001 004 detailed view Mounting example 3 2 Manufacturer 4 3 Product information 4 4 General warnings and security measures 4 5 Testing 4 6 Warranty 4 7 Disposal and recycling 5 8 Notes 5 9 Device features 5 10 Operation and installation 6 10 1 Step by step installation guide 6 10 2 Operation description 6 10 3 Activation deactivation 6 10 1 App features 7 10 2 Battery replacement 8 ...

Page 3: ...opyright AVK Holding A S original version rev 4 05 MAY 2021 1 AVK series and type 3001 004 detailed view Mounting example NOTE AVK has valves available with bosses for mounting additional equipment Please contact local AVK sales representatives for more information ...

Page 4: ...structions Installation must be carried out by personnel who are properly trained to operate on plants where they will be able to install the device Therefore it is absolutely forbidden to install the device if you are unexperienced The device must be installed in sufficiently airy places to prevent any internal overheating Do not place the device in the vicinity of living flames such as candles t...

Page 5: ...t disposal and recycling are always respected 8 Notes All rights to this manual are exclusive to the Manufacturer Copying and translating this manual is prohibited without a written permission from the owner The Manufacturer reserves the right to modify the technical specifications or functions of its products to cease production of one of its products or to discontinue technical support for one o...

Page 6: ...ansmitter sends a data package every 30 minutes containing a message with the measured values with five minutes resolution In case an alarm is detected tamper or battery alarm an additional data package is sent immediately 10 3 Activation deactivation Transmitters are shipped with radio mode off Once the installation of the transmitter is complete the transmitter must be activated This is done by ...

Page 7: ...ctivated which is described in this section Read distance This button allows the user to read a local distance measurement immediately once pressed The returned value is from 0 100 which corresponds to the total range of the level sensor example The measured value on the phone s display shows 50 0 and using a level sensor 0 5 meter the real distance value is 2 5 meters During field testing and dev...

Page 8: ...mal conditions and use The battery replacement can be done by opening the container and replacing the battery enclosed Replace it with a battery of the same characteristics the same connector and the same polarity Battery type Non rechargeable lithium ions Tension 3 6 V Capacity 9000 mAh Size C Once the battery is replaced in the case of LoRaWAN transmitters the message counters are reset to zero ...

Reviews: