NOTE:
When the TACP is connected to the MCC-8001U, ACC-8000, and Rainier-4U1V and
RS-232 is selected as the communication port, a RS-232 splitter cable is required.
Due to space limitation, the serial connector is replaced with a RJ-45 connector. A
proprietary RJ-45 to RS-232 (DB9-FM) cable is needed for serial function. The pin
definition is shown next.
DB9-FM RJ-45
Pin Assignment Pin Assignment
1
1
Tx
2 Tx
2 Gnd
3 Rx
3
4
4
Rx
5 Gnd
5 Gnd
6
6
7
7
8 5
V
8 5
V
9
1.2
Product Features
Hardware
Direct communication with up to 120 modules on one TACP (including
seven IP and one RS-232 connection).
Peer-to-peer communication among TACPs.
Ethernet and serial connectivity.
3