background image

Warning:

 If the accuracy of any measurement is in question or the use of 

this thermometer is not appropriate due to patient condition, check the pa-
tient's temperature with an alternate method and then check to verify the 
device is functioning properly by comparing it against a calibrated reference 
device. 

 

Warning:

 Keep this thermometer and its batteries out of the reach of  

children. Do not allow children to take their temperature with this 
thermometer unattended. 

 

Warning:

 Dispose of this thermometer and its batteries in accordance with 

local or national regulations for electronic waste. 

 

Caution

: When replacing the batteries, always replace both batteries and 

ensure that they are of the type and specification indicated in this manual. 
Observe correct polarity when inserting new batteries. 

 

Caution:

  Do not use rechargeable batteries. The use of rechargeable 

batteries may compromise the performance of this device. 

 

Caution:

 Remove the batteries whenever the device is not expected to be 

used for an extended period of time. 

 

Caution

: If battery leakage occurs, fully clean the battery compartment 

using personal protective equipment prior to re-use.   

 

Caution

:  Observe proper measurement distance, starting between 4 and 6 

cm from the patient's forehead. This is essential to the accuracy of the 
measurement. 

 

Caution:

  Do not modify or disassemble this device in any way without prior 

authorization. 

 

Caution:

 To avoid accuracy concerns, make sure that the thermometer’s 

lens is clean and intact prior to use and after measurement is complete. 

 

Caution:

 Avoid touching the lens directly with your fingers. 

 

Caution:

 Do not expose the thermometer to extreme temperatures or 

humidity levels. 

 

Caution:

 Do not expose to direct sunlight. 

 

Caution:

 The thermometer is not waterproof; do not immerse in water or any 

other liquid.

 

6

15

11. Technical Specifications 

Type Non-Contact infrared thermometer 

Model no. 429 

 
Measuring Range: 

      Human Mode:                     

50.0°F ~ 122.0°F 

                                                   (10°C ~ 50°C) 

 

      Object Mode:                      

32.0°F ~ 212.0°F 

                                                   (0°C ~ 100°C) 

 

Calibration Accuracy:               

      Human Mode:

                    71.6°F ~ 104.0°F: ±0.5°F 

                                                   (22°C ~ 40°C): ±0.3°C 

 

      Object Mode:

                      ≤ 68°F: ± 1°F

(≤ 20°C: ± 1°C) 

                                                   > 68°F: ± 5%

(> 20°C: ± 5%) 

 

Display Resolution:

                  0.1°F   (0.1°C) 

 

Operating Environment:

          60.8°F ~ 104°F 

                                                   (16°C ~ 40°C) 
                                                   with relative humidity up to 95% 
                                                   (non condensing) 

 

Storage/Transportation 
Environment:

                            -4°F ~ 122°F 

                                                   (-20°C ~ 50°C) 
                                                   with relative humidity up to 95% 
                                                   (non condensing) 

 

Power Supply:

                          2x 1.5V AAA size alkaline batteries 

 

Weight:

                                      Approximately 3 oz  /  87 g  (with batteries) 

 

Dimensions:

                              Approximately 2.06” x 1.75” x 5” 

                                                   52.4 mm x 44.5 mm x 129.9 mm (LxWxH) 

 

Operation Distance:

                 Starting approximately 1.57” - 2.36” 

                                                   4 ~ 6 cm (±1 cm)

 

 

Auto Off:

                                

After 30 seconds of inactivity

 

 

Battery Life:

                           

2,000-2,500  measurements

50° F

10° C

122.0° F

50° C

32.0° F

0° C

212.0° F

100° C

71.6° F

22° C

104.0° F

40° C

60.8° F

16° C

104.0° F

40° C

-4° F

-20° C

122° F

50° C

93-429-00 Small IFU rev 6.qxp_Layout 1  4/1/20  12:06 PM  Page 6

Summary of Contents for ADTEMP 429

Page 1: ... REP Distributed by American Diagnostic Corporation 55 Commerce Drive Hauppauge New York 11788 Inspected in the U S A Made in China tel 631 273 9600 1 800 232 2670 fax 631 273 9659 www adctoday com email info adctoday com 0598 93 429 00 Small IFU rev 6 qxp_Layout 1 4 1 20 12 06 PM Page 1 Contract Manufacturer AViTA WuJiang Co Ltd Tel 86 512 8207 8288 Address No 858 Jiao Tong Rd Wujiang Economic De...

Page 2: ...ter is sure to provide you with many years of dependable service Please read the following instructions and general information which will prove helpful in allowing you to enjoy your ADC product Read this booklet thoroughly before attempting to use your new ADC Adtemp thermometer Thank you for your patronage It is indeed our pleasure to serve you Sincerely American Diagnostic Corp 2020 AMERICAN DI...

Page 3: ...e for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 14 Warranty This thermometer is guaranteed for a period of 24 months from date of purchase This warranty does not cover batteries or damage resulting from improper handling or use Specific legal righ...

Page 4: ...PMENT and ME SYSTEM used will be connected to the PUBLIC MAINS NETWORK and the power input is otherwise within the scope of the Basic EMC standard Guidance and manufacturer s declaration Electromagnetic immunity Enclosure port a The equipment is suitable for use in Home Health Environments and Professional Health Care Environments limited to patient rooms and respiratory treatment facilities in ho...

Page 5: ...els characteristic of a typical location in a typical commercial or hospital environment Guidance and Manufacturer s Declaration Electromagnetic emissions 16 5 2 Introduction Intended Use Intended use The Adtemp Non Contact thermometer is a clinical grade device intended for the intermittent measurement of human body temperature in patients of all ages It can also be used to measure the temperatur...

Page 6: ...ution Do not modify or disassemble this device in any way without prior authorization Caution To avoid accuracy concerns make sure that the thermometer s lens is clean and intact prior to use and after measurement is complete Caution Avoid touching the lens directly with your fingers Caution Do not expose the thermometer to extreme temperatures or humidity levels Caution Do not expose to direct su...

Page 7: ...thermometer for an excessive period of time or exposing the device to external heat sources may result in distorted temperature readings 14 7 10 Disposal The thermometer contains no hazardous materials Discard in accordance with national or local regulations Remove the batteries before disposal Battery Dispose of empty batteries in accordance with national or local regulations 9 Calibration Testin...

Page 8: ...chieved using the following method CAUTION Never submerge the thermometer in water or any other liquid CAUTION Never use abrasive cleaning agents thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids CAUTION Never insert a sharp object into the scanner area or any other open surface on the thermometer CAUTION Do not use unapproved cleaning or disinfec...

Page 9: ...n 4c for instructions on selecting a different scan mode 3 Position the thermometer about 2 inches 5 cm from the center of the patient s forehead with the sensor aimed between the eyebrows 8 Maintenance 8a Replacing the Batteries The thermometer comes with two 1 5V AAA LR03 alkaline batteries Replace with two new AAA LR03 batteries when the low battery symbol appears on the display The thermometer...

Page 10: ...on is pressed and released you will have 20 seconds to obtain a temperature reading After 20 seconds the unit returns to standby mode 6 To repeat the process return to step 2 7 The thermometer automatically turns off with a single beep after 30 seconds of inactivity Note The device cannot be turned off manually Note The Human or Object symbols will be displayed to indicate the measurement mode tha...

Reviews: