2D
Parallel Only
OFF
Panachrome
+
has 48 parallel beams and the option to activate
or deactivate a further 186 diagonal beams. Choose to have
parallel beams only ON or OFF
ON
Timeout/EN81-20
OFF
This enables/disables 2D timeout for up to 5 non-adjacent
infra-red diodes
ON
Timeout Period
Beam timeout time (10 to 360s)
Cdn TMO Period
Canadian timeout time setting (not enabled)
Sleep
OFF
Turn sleep mode ON or OFF. Default OFF
ON
3D
Enable
OFF
Enable/disable 3D detection. Default OFF for 2D only
detectors (G2510 or G2540) and has no effect
ON
Mode
See Section 7 for more details
ON at Closing
3D activates when the doors are closing
ON at 800mm
3D activates when the doors are approx. 800mm apart
ON Always
3D always on with no 3D timeout
ON (10s)
3D always on with 10s 3D timeout
ON (20s)
3D always on with 20s 3D timeout
Sensitivity
High
3D sensitivity settings. Choose according to installation. If false
triggering on High then choose a lower sensitivity
Intermediate
Low
Timeout Count
Counts the 3D triggers (2 to 10) and disables 3D once this count
is reached. Note: resets with a 2D trigger or doors fully closed
Second Relay
Copy Main
Relay 2 mimics main relay (relay 1)
EN81-20 Mode
Relay 2 activates when EN81-20 conditions are not met.
This can be that a diode(s) has timed out which means the
50mm target detection is now not met, or a system fault has
developed
Canadian
Canadian timeout. If a trigger is on for the timeout period (Cdn
TMO) then the relay will activate
Disabled
Relay 2 disabled
Audio
Beeper
OFF
Beeper off
Beep ON
Beeper active on a trigger
Beep Closing
Beeper active when the doors are closing and triggered
Speech
OFF
Speech output OFF
ON
Speech output ON
Speech Volume
Speech volume (0 to 9). Note: 0 volume is lowest setting and
not equivalent to OFF
Speaker
Internal
Enable internal speaker.
External