background image

29

Av-P2 O

utPut

 M

Odule

 u

ser

 G

uide

I

inline coupler  10

L

LAN

Local Area Network  6

line‑level

connecting  18

Local Area Network  6

long distance A‑Net  24

M

maximum cable length  10

media converter  24

Mic Input Module  2

mono  14

mounting flanges  12

Mute Switch  3, 13

N

network  6

networking  6
Neutrik EtherCon. 

See

 EtherCon

O

Output Level  13, 21

output level DIP switches  13

Output Level DIP Switches  3

P

Package Contents  1

Panel Descriptions  13

Parallel A‑Net Routing  23

parallel connection  23

permanent installation  8

Power Connector  16

Power LED  3, 15

power supply

plug size  10

replacing  10

Power Supply  1625

power supply polarity  11

Pro16  1, 6

Pro64  5, 7

R

rack mounting  12

Rear Panel Components  4

Rear Panel description  16

replace the power supply  10

RJ45 connector  7

RoHS  ii

router  6

S

series connection  23

Setting Output Level  21

signal repeater  24

Specifications  25

stereo  14

Stereo Link  14

Stereo Pair LED  3, 14

System Bridge  5

U

Unbalanced Source

wiring Euroblocks  19

Unshielded Twisted Pair  7

UPS  10

UTP  7

W

Wiring a Euroblock  18

Y

Y1 card  5

Yamaha  5

Summary of Contents for AV-P2

Page 1: ...ARTWORK LABEL ID AV P2 P N 9225 1071 0001 REV A SCALE 1 1 26 JAN 07 PRO16 AV P2 P N 9310 1019 0001F rev 2 00 2009 Aviom Inc User Guide...

Page 2: ...t to change without notice Notice of Rights All rights reserved No part of this document may be reproduced or transmitted in any form or by any means electronic mechanical photocopy recording or other...

Page 3: ...cles and the point where they exit the apparatus Only use attachments accessories specified by the manufacturer 11 Use only with the cart stand tripod bracket or table specified by 12 the manufacturer...

Page 4: ...N Using any audio system at high volume levels can cause permanent damage to your hearing Set your system volume as low as possible Avoid prolonged exposure to excessive sound pressure levels IMPORTAN...

Page 5: ...ress phone number description of the problem and copy of the original bill of sale with the shipment The Return Authorization number should be written on the outside of the box THIS LIMITED WARRANTY G...

Page 6: ...web site at www aviom com To fulfill warranty requirements your Aviom product should be serviced only at an authorized Aviom service center The Aviom serial number label must appear on the outside of...

Page 7: ...10 Power Supplies 10 Cleaning and Maintenance Information 11 Mounting the AV P2 12 Panel Descriptions 13 AV P2 Front Panel 13 Audio Output Levels 13 Mute Switch 13 A Net Channel Selector 14 Stereo Pa...

Page 8: ...ix AV P2 Output Module User Guide Parallel A Net Routing 23 Using an A Net Distributor 23 Extending A Net Cable Runs 24 Specifications 25 Dimensions 26 Block Diagram 27...

Page 9: ...put Module Features Two balanced line level audio output channels Individual output levels for each channel Audio output level DIP switches Euroblock terminal block audio connections Dual mono or ster...

Page 10: ...al monitor system using any combination of the AV P2 AN Series I O modules and Personal Mixer products including the A 16II and A 16R When referring to the use of the personal mixers in a system in ge...

Page 11: ...tch 3 A Net Channel Selector 4 Stereo Pair LED 5 A Net Active LED 6 Power LED 7 Reversible Mounting Flanges LEFT RIGHT MUTE CHANNEL STEREO PAIR A NET ACTIVE POWER AV P2 OUTPUT LEVELS 1 2 3 4 5 6 7 8 9...

Page 12: ...anel Components 1 DC Power Connector 2 Audio Output Euroblock Connectors 3 A Net Out Port 4 A Net In Port LEFT DC POWER RIGHT OUT IN AUDIO OUTPUT AV P2 18 24 VDC 500mA v w x 4 AV P2 Output Module User...

Page 13: ...Mixer A 16II Personal Mixer A 16D A Net Distributor A 16D Pro A Net Distributor AN 16 o Output Module AN 16SBR System Bridge In addition to the Aviom devices mentioned above the AV P2 Output Module c...

Page 14: ...Network or LAN technology This provides A Net with a mature and robust base on which to build However it is important to note that A Net devices are not compatible with Ethernet devices As used in th...

Page 15: ...ta transmission purposes to connect computers modems and other devices A standard Category 5 patch cable consists of four twisted pairs of copper wire terminated by RJ45 male connectors The cable asse...

Page 16: ...ck Solid wire is recommended for permanent installations In addition to standard Category 5e cables Category 6 Cat 6 and Cat 6e cables can also be used P Note When purchasing Category 5e cables be sur...

Page 17: ...performance wherever possible Stranded or solid Cat 5e cable can be used When using the optional AN 16SBR System Bridge the cable length specification applies to the total cable length between the tw...

Page 18: ...uipment Other options for protection of your equipment include the use of an AC line conditioner or a battery backup system sometimes referred to as an uninterruptible power supply or UPS Power Suppli...

Page 19: ...act is negative the inner contact is positive See the diagram above Cleaning and Maintenance Information The exterior of your Aviom products should be cleaned with a dry soft lint free cloth For tough...

Page 20: ...ing only a Phillips head screwdriver Each mounting flange contains holes for two screws per side Always support the unit with all four screws when attaching the product to a flat surface If desired th...

Page 21: ...UTE CHANNEL STEREO PAIR A NET ACTIVE POWER AV P2 OUTPUT LEVELS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ON The AV P2 front panel interface Audio Output Levels Individual DIP switches are provided for le...

Page 22: ...dio channels have separate output level settings When using mono A Net channels this allows two different output levels to be set if desired Stereo Pair LED The Stereo Pair LED will light whenever the...

Page 23: ...ly is connected to a valid AC power source or when it is receiving power over the Cat 5 connection It does not however indicate that a valid A Net digital stream is being received That is the job of t...

Page 24: ...pply This type of power supply can be used worldwide with a wide range of AC wall current output voltages 100 240VAC When traveling you do not need to replace the power supply in countries where volta...

Page 25: ...f the AV P2 Output Module There is one A Net In port and one A Net Out port The A Net In port receives digital data in Aviom s proprietary A Net format The A Net Out port is used to pass incoming A Ne...

Page 26: ...Euroblock audio outputs Connecting to a Balanced Device To connect the AV P2 Euroblock audio output to a device that can accept a balanced line level input Strip the insulating jacket of the cable bac...

Page 27: ...nch 1 18 mm to reveal the individual hot and ground wires within Remove a small amount of each individual wire s insulation 2 approximately 25 inch 6 mm On the Euroblock plug use a small screw driver...

Page 28: ...t the audio cable s hot wire into the matching 4 socket on the Euroblock plug Insert the audio cable s cold wire into the matching 5 socket on the Euroblock plug Insert the audio cable s ground wire i...

Page 29: ...on the front panel Individual settings are possible for the left and right audio channels LEFT RIGHT MUTE CHANNEL OUTPUT LEVELS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ON The AV P2 front panel interfa...

Page 30: ...L dB 1 1 1 1 1 1 0 1 1 1 1 1 0 1 2 1 1 1 1 0 1 2 9 1 1 1 1 0 0 4 6 0 1 1 1 1 1 5 7 0 1 1 1 1 0 6 9 0 1 1 1 0 1 8 6 0 1 1 1 0 0 10 3 0 1 0 1 1 1 12 9 0 1 0 1 1 0 14 1 0 1 0 1 0 1 15 8 0 1 0 1 0 0 17 5...

Page 31: ...onnected to a valid A Net source Series Connection of A Net Devices A Net In Out A Net In Out A Net In Out A Net In Out In this diagram A Net is connected from device to device using Cat 5e cables The...

Page 32: ...r A 16D Pro A Net Distributor can be used as a signal repeater Simply insert the A 16D or A 16D Pro into the A Net stream at the 500 foot point and the A Net signal will be refreshed Another 500 feet...

Page 33: ...pical A D to D A Measured from AN 16 i Input Module to AV P2 Freq Response 4Hz 22kHz 0 2dB 3dB THD N 93dB at 10dBFS Crosstalk 85dB at 1kHz Bit Error Rate BER 10 12 Digital Connections A Net In 1 A Net...

Page 34: ...Dimensions 26 AV P2 Output Module User Guide...

Page 35: ...Block Diagram Channel select Audio Output L R Euroblock A Net D A converter Level control 4dBu to 31dBu 1 5dB steps Mute Audio Out _ 27 AV P2 Output Module User Guide...

Page 36: ...m Interface 5 ASI A Net Systems Interface 7 Audio Output Level 13 Audio Outputs 16 AV M8 Mic Input Module 5 AV P2 6 B balanced signal connecting 18 Block Diagram 27 C cable length 8 Cat 5 7 8 9 Cat 5e...

Page 37: ...iptions 13 Parallel A Net Routing 23 parallel connection 23 permanent installation 8 Power Connector 16 Power LED 3 15 power supply plug size 10 replacing 10 Power Supply 16 25 power supply polarity 1...

Page 38: ...fax All information will be kept confidential Model Number Serial Number Model Number Serial Number Model Number Serial Number Model Number Serial Number Date Purchased Dealer Name Dealer Location Yo...

Page 39: ...1157 Phoenixville Pike Suite 201 West Chester PA 19380 Voice 1 610 738 9005 Fax 1 610 738 9950 www Aviom com...

Reviews: