E-48
Maintenance
5
Reset the lamp usage time
Please perform the operation indicated below in the
standby mode (*).
6
Check that the indication of the lamp us-
age time has become “0 H” as illustrated
in the diagram to the right.
If the usage time has not been reset, please reset it by
following Step
5 again.
Check the lamp usage time by pressing the menu button of
the remote control to display the menu, then use the scroll
◀▶
button to display the setup setting.
Operation with the Projector
Press the INPUT, PORTRAIT, FREEZE OFF and FREEZE/CAPTURE buttons si-
multaneously, then press the input selector and still picture buttons simultaneously.
Operation with the Remote Control
Resetting of the lamp usage time cannot be performed with the remote control.
The LAMP/COVER LED will flash green following this and projection will start.
* The power plug is plugged into a power outlet and only the ON/STANDBY LED is lit red.
CAUTION
• If the lamp is used without resetting the usage time, the correct lamp usage time will not be known;
therefore, be sure to reset the usage time after lamp replacement. When the indication exceeds 2000
hours, the projector will be forced to turn off the projection lamp.
NOTE:
• In the interest of safety, the lamp will not light when the lamp unit cover is off.
• Like fluorescent bulbs for home use, the lamp unit contains a trace amount of mercury. When disposing of it, do so following
the same regulations in place in your community as for fluorescent bulbs.
CAUTION
• Do not reset the lamp usage time without replacing the lamp.
The likelihood of the lamp rupturing becomes higher when the lamp has been used in excess of 2000
hours.