background image

Important Safety Information

This manual provides installation and operation information and precautions for the use of this camera. Incorrect
installation could cause an unexpected fault. Before installing this equipment read this manual carefully. Please
provide this manual to the owner of the equipment for future use.

The Warning symbol indicates the presence of dangerous voltage within and outside the product
enclosure that may constitute a risk of electric shock, serious injury or death to persons if proper
precautions are not followed.

The Caution symbol alerts the user to the presence of hazards that may cause minor or moderate injury
to persons, damage to property or damage to the product itself if proper precautions are not followed.

WARNING —

Failure to observe the following instructions may result in severe injury or death.

l

Installation must be performed by qualified personnel only, and must conform to all local codes.

l

This product is intended to be used in an Network Environment 0 per IEC TR62101. The camera is to be
connected only to PoE network that complies with IEEE 802.3af without routing to the outside plant.

CAUTION —

Failure to observe the following instructions may result in injury or damage to the camera.

l

Do not install near any heat sources such as radiators, heat registers, stoves, or other sources of heat.

l

Do not subject the cables to excessive stress, heavy loads or pinching.

l

Do not open or disassemble the device. There are no user serviceable parts.

l

Refer all servicing to qualified personnel. Servicing may be required when the device has been damaged
(such as from a liquid spill or fallen objects), has been exposed to rain or moisture, does not operate
normally, or has been dropped.

l

Do not use strong or abrasive detergents when cleaning the device body.

l

Use only accessories recommended by Avigilon.

Regulatory Notices

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.

This Class B digital apparatus complies with Canadian ICES-003.

ii

Summary of Contents for 1.0-H3M-DP1

Page 1: ...Installation Guide Avigilon High Definition H 264 IP Micro Dome Camera Models 1 0 H3M DP1 and 2 0 H3M DP1...

Page 2: ...t 0 per IEC TR62101 The camera is to be connected only to PoE network that complies with IEEE 802 3af without routing to the outside plant CAUTION Failure to observe the following instructions may res...

Page 3: ...on could void the user s authority to operate this equipment Disposal and Recycling Information When this product has reached the end of its useful life please dispose of it according to your local en...

Page 4: ...hout notice Avigilon reserves the right to make changes without notice in the specifications and materials contained herein and shall not be responsible for any damages including consequential caused...

Page 5: ...4 Connecting Power Over Ethernet PoE 7 Mounting the HD Micro Dome Camera 9 Assigning an IP Address 9 Accessing the Live Video Stream 9 Aiming the HD Micro Dome Camera 10 For More Information 12 LED In...

Page 6: ...Overview Housing View 1 Dome Cover Attaches the camera dome bubble to the camera housing 2 1 5 Thread Thread for mounting the camera onto the mounting conduit 1 Overview...

Page 7: ...a vertical reference point for the video image Points up 2 Horizon Markers Provide reference points for aligning the video image with the horizon line 3 Gimbal Allows you to move and aim the camera af...

Page 8: ...vides information about device operation For more information see LED Indicators on page 13 3 Ethernet Port Accepts power and Ethernet connection to the network The camera can only be powered by Power...

Page 9: ...r l Foam Sealing Gasket Installation Steps Complete the following steps to install the device Preparing for the Installation 4 Connecting Power Over Ethernet PoE 7 Mounting the HD Micro Dome Camera 9...

Page 10: ...1 Connect the NPT adapter l If using the provided 3 4 NPT adapter a Wrap the threads at the end of the mounting conduit three to five times with Teflon tape 5 Preparing for the Installation...

Page 11: ...ther adapter a Attach the adapter to the mounting conduit NOTE If using a different adapter than the one provided by Avigilon ensure that the camera housing is sealed from moisture 2 Preparing the Eth...

Page 12: ...of the mounting conduit s Ethernet cable with an Ethernet connector Connecting Power Over Ethernet PoE NOTE The HD Micro Dome camera can only be powered by Power over Ethernet PoE 7 Connecting Power O...

Page 13: ...1 Place the foam gasket onto the camera housing 2 Connect the mounting conduit s Ethernet connector to the camera s Ethernet port Connecting Power Over Ethernet PoE 8...

Page 14: ...the 169 254 0 0 16 subnet The IP address settings can be changed using one of the following methods l Camera s web browser interface http camera IP address l ARP Ping method For more information see S...

Page 15: ...ng NOTE You must hold the housing to ensure that the camera housing does not rotate Do not hold the camera dome bubble The resulting fingerprints may affect the overall image quality 2 Turn the gimbal...

Page 16: ...er back onto the base NOTE You must hold the base to ensure the camera does not rotate Do not hold the camera dome bubble The resulting fingerprints may damage the overall image quality 11 Aiming the...

Page 17: ...ing the device is available in the following guides l Avigilon Control Center Client User Guide l Avigilon High Definition H 264 Web Interface User Guide The manuals are available on the Avigilon webs...

Page 18: ...Connection Status LED Description Obtaining IP Address One short flash every second Attempting to obtain an IP address Discoverable Two short flashes every second Obtained an IP address but is not co...

Page 19: ...e 1 The firmware revert button on the cable assembly 1 Disconnect power from the device 2 Using a straightened paperclip or similar tool gently press and hold the firmware revert button 3 While contin...

Page 20: ...ence 2 Open a Command Prompt window and enter the following commands a arp s New Camera IP Address Camera MAC Address For example arp s 192 168 1 10 00 18 85 12 45 78 b ping l 123 t New Camera IP Addr...

Page 21: ...finger prints l Use a microfiber cloth or non abrasive fabric to dry the dome bubble Important Failure to use the recommended cleaning materials may result in a damaged or scratched dome bubble that...

Page 22: ...SP HTTP TCP RTP RTSP HTTPS TCP Mechanical Dimensions xH 77 20 mm x 153 80 mm 3 03 x 6 06 Weight 466 g 16 44 oz 58 g 2 05 oz for adapter Body Aluminum Housing Pendant mount vandal resistant Optional 1...

Page 23: ...Weather Rating Electromagnetic Emissions FCC Part 15 Subpart B Class B EN 55022 Class B IC ICES 003 Class B Electromagnetic Immunity EN 55024 Class B EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4...

Page 24: ...gents or employees shall create another warranty or modify this warranty This warranty states Avigilon s entire liability and your exclusive remedy against Avigilon for any failure of this product to...

Reviews: