SkyTrax Pilot Guide
SkyTrax Operations 1-7
LATENCY TIMING PERFORMANCE
Traffic Latency
Maximum traffic latency
within the ST100B/ST200
= 1.75 seconds
Ownship Position Latency
Maximum ownship
position latency within the
ST100B /ST200 = 1.75
seconds
Maximum ownship position
latency from the position
source = 1.0 seconds
Display Latency
Maximum latency from
receiving a complete
update to a updated
display to the pilot = 0.75
seconds
AVIONICS INTERFACES
Annunciator Outputs
Capable of sinking 500mA
for turning on annunciator
lamp
Control Port
RS232 asynchronous serial
Maintenance Port
USB asynchronous serial
External Position Input
RS232 asynchronous serial
or
ARINC743A GNSS sensor
Display/Control
RS232 asynchronous serial
(Pass-through or Traffic Alert
interfaces)
ARINC735 Traffic interface