Avidyne DC50 Datalink Coupler Installation Manual
Page 14
P/N 600-00082-000 Rev 04
7 Environmental Qualification Form
Nomenclature: DC50 VHF/Datalink Coupler
Type /Model/Part Number: 700-00015-XXX-()
TSO Compliance: C37d and C38d
Manufacturer: Avidyne Corporation
Address: 55 Old Bedford Rd. Lincoln, Ma, 01773
Environmental
Tests
RTCA/DO-160D
Section
Conducted Test
Category
Temperature and
Altitude
Low Temp
4.5.1
Equipment tested to
Category A1
High Temp
4.5.2 & 4.5.3
Equipment tested to
Category A1
In-Flight Loss of
Cooling
4.5.4
Equipment tested to
Category Y
Altitude
4.6.1
Equipment tested to
Category D1
Decompression
4.6.2
Equipment tested to
Category A1
Overpressure
4.6.3
Equipment tested to
Category A1
Temperature
Variation
5
Equipment tested to
Category C
Humidity
6
Equipment tested to
Category A
Operational Shocks
& Crash Safety
7
Equipment tested to
Category B
Vibration
8
Equipment tested to
Category S, Curve B & M