Page 1: ...Puro Range Water Purification System PURO10 PURO20 PURO50 PURO80 Series 3 Operation Manual OP 000106 Revision A March 2019...

Page 2: ...ty Science LLC assume liability for damages to your system resulting from the use of the information in this manual Information in this document is subject to change without notice and does not repres...

Page 3: ...Support v Introduction 1 Puro Water Purification Models 1 Purification Process 1 Primary Operation Menus and Sub menus 3 Operation 5 User Settings 5 System Settings 5 Consumable Timers 5 Alarms Warnin...

Page 4: ...Puro Range Water Purification System Operation Manual Avidity Science LLC ii Contents This page left intentionally blank...

Page 5: ...TIONS RoHS WEEE Statement Avidity Science LLC water treatment automated watering environmental monitoring and access control systems specified in this manual are manufactured in compliance with the Ro...

Page 6: ...ARNING Toxic gas Do not add acid to the chlorine solution tank Mixing of chlorine and acid will produce a toxic chlorine gas that can result in death or personal injury WARNING Severe personal injury...

Page 7: ...the tables below UK Support US Support China Support CAUTION Equipment Damage Follow all nationally and locally approved elec tricial codes when installing and operating this equipment Failure to do...

Page 8: ...Puro Range Water Purification System Operation Manual Avidity Science LLC vi Important Safety and Service Information This page left intentionally blank...

Page 9: ...emoved for access to replaceable components All recorded data warning messages and dispensing information can be viewed from the controller dis play Puro Water Purification Models The content in this...

Page 10: ...to pass through the RO membrane again conserving water The product water referred to as permeate is measured through the Permeate Conductivity Sensor Q2 as it leaves the membrane When the water qualit...

Page 11: ...Menus and Sub menus red Access Main menu View Active Alarms Main Menu Password Required External Storage Tank is Filling optional Access information related to the displayed screen green Turn off the...

Page 12: ...Puro Range Water Purification System Operation Manual Avidity Science LLC 4 Introduction This page intentionally blank...

Page 13: ...gs This is the User Settings screen RO Quality Limit Set the required water quality of the Type 3 water Tank Full Limit Set the Full water level for the external storage tank if applicable System Sett...

Page 14: ...arms will automatically display as they occur Touch the alarm name to display details Below is a sample alarm screen Touch to acknowledge the alarm The alarm will stay in the list until the associated...

Page 15: ...1 On or touch then on touch 2 Enter the required passcode and touch 3 Touch the applicable setting and touch 4 Touch or until the desired value is displayed 5 Touch 6 Touch to return to the User Sett...

Page 16: ...reen instructions Permeate Sensor Fault LOW 64 Follow on screen instructions Loop Conductivity Sensor Fault 63 Follow on screen instructions Temperature Sensor HIGH 64 Allow system to flush Temperatur...

Page 17: ...ect 3 Enter the User passcode and touch 4 On touch TC001 Change and touch The pre treatment module depressurizes NOTE Use or as necessary to make the selection 5 When Disconnect TC001 and remove is di...

Page 18: ...n the new module with the printed arrows pointing up 9 Connect the applicable elbow fitting to each end of the module as shown below 10 Secure the module to the two brackets 11 Replace the left front...

Page 19: ...e the threaded screw caps from the RO membrane housing 6 Remove the RO membrane module from the housing 7 Insert a new membrane module into the RO membrane housing 8 Secure the threaded screw caps to...

Page 20: ...e air filter TC005 The air filter connects to the top of the storage tank Follow this procedure 1 Remove the new air filter from its packaging 2 Pull the existing filter off the top of the tank 3 Turn...

Page 21: ...00 125 TC026 RO Membrane for PURO80 4 2200 7120 010 TC008 UV Lamp External Storage Tank 7120 3500 102 TC005 Air Filter External Storage Tank Table 5 Replacement parts US Part Number European Part Numb...

Page 22: ...2200 128 LEAD00001 Power Cord UK 1 7120 2200 129 LEAD00002 Power Cord EU 1 7120 2200 127 LEAD00004 Power Cord US 1 7120 2200 131 LEAD00005 Power Cord China0 1 7120 2200 124 WIRE00014 Power in Cable 1...

Page 23: ...or 1 2400 2311 101 SENS00009 Pressure Sensor 0 to 10 bar 100 litre Tank with pump 1 6700 2311 102 FUSE00002 Fuse 100 litre Tank with 230V pump 1 6700 2311 101 FUSE00003 Fuse 100 litre Tank with 115V p...

Page 24: ...Puro Range Water Purification System Operation Manual Avidity Science LLC 16 Consumables and Replacement Parts...