Chapter 2: Pro Tools | MTRX Operation
7
Operating Buttons
Setting
Pushing the
Setting
button scrolls trough the settings rows. The > cursor marks the selected row/function.
Up
Pushing the
Up
button scrolls up the value/setting of the selected function.
Down
Pushing the
Down
button scrolls down the value/setting of the selected function.
Page
Pushing the
Page
button scrolls trough the available display pages.
Basic Display Page
(Sample Rate, Synchronization, ID, and Alarms)
Sample Rate
Shows the sample rate of the MTRX. If an asterisk * is shown, the sample rate is controlled by an external digital audio
interface.
SRate Adapt
Shows which external digital audio interface controls the sample rate, or it shows
Intern
for internal sample rate control.
Sync Source
Shows the external synchronization clock source, or shows
Intern
when the MTRX is using the internal clock.
Unit ID/Name
Shows the unit ID number and unit name. This is configured using DADman software.
Alarm/Status
Shows the alarm status indicating Clock Sync or an operational error.
Alarm/Status Display
Description
Sync OK
Clock sync is OK.
SyncErr
Clock sync failure.
TempErr
The temperature inside MTRX is above 60ºC/140ºF. Check that the MTRX is properly
installed to allow airflow.
Fan Err
One of the two fans is not working correctly. Contact an Avid representative.
CardErr
Fault in one of the A/D or D/A cards. Contact an Avid representative.
Psu Err
Power supply failure. Contact an Avid representative.
Setting
Up
Down
Page
Pro Tools
| MTRX
PT HD1
Sample Rate
*
>
:
SRate Adapt
Sync Source
1:NameUnit
48
Intern
Sync OK